Cabletron Systems CSMIM2-16 Installation Manual page 95

Communications server module
Table of Contents

Advertisement

Press the Setup switch within 3 seconds of powering–up.
NOTE
5.
The MODMIM runs its ROM–resident power–up diagnostics:
All indicators light momentarily and then turn off.
The Traf indicator flashes to show that diagnostics are running.
If the diagnostics complete successfully, the Stat and Attn
indicators light. After about one minute, the ROM Monitor prompt
appears on the console terminal.
6.
Issue the config command to verify the new hardware and port
configuration.
7.
The console responds with the board configuration. Check the heading
"MODEM Config" to insure that the correct number of modem ports
were recognized (either 8 for the MODEXT-4 or 12 for the
MODEXT-8).
8.
At the monitor prompt, execute the boot command.
CSMIM2 Installation Guide
MODMIM Power–up and Test
D-3