Chapter 4: Troubleshooting Procedures
ARP errors
ERPC layer errors
Aborts rx'd
Msgs with wrong size
ERPC layer errors
Aborts rx'd
Table 4-7 Errors from Last ERPC Layer Invocation
H/W errors
Msgs from wrong host
Rsp T/O's
Msgs of wrong type
4-8
Table 4-5 Errors from Last Open Request
Address Resolution Protocol (ARP) errors indicate that
the CSMIM2 is configured to boot from a specified host,
but the host would not transmit its Ethernet address to the
CSMIM2. Possibly, the CSMIM2 configuration includes
the wrong IP encapsulation.
See Errors from Last ERPC Layer Invocation below.
The host's BFS transmitted an abort in response to the
CSMIM2's Open Request. This often means that the
requested file does not exist on that server. Run erpcd -D
on the host to obtain more information.
Table 4-6 Errors from Last Read Request
The correct host responded to the Read Request, but the
data size is incorrect.
See Errors from Last ERPC Layer Invocation below.
The host's BFS transmitted an abort in response to the
CSMIM2's Read Request. Run erpcd -D on the host to
obtain more information.
The CSMIM2 sensed a hardware error during
message transmission or reception. This error
indicates a fault with the CSMIM2 network interface.
Use the net command to isolate the problem (see
Chapter 3).
The CSMIM2 received a message from an incorrect
host. This indicates that the CSMIM2 received, and
ignored, an unsolicited packet.
The CSMIM2 never received a correctly formatted
response from the correct host, or any response
from any load server hosts.
The correct host sent a message to the CSMIM2,
but the message was not a correctly formatted
response to the transmitted request.
CSMIM2 Installation Guide