4.2.2.4

Activity T3: At the Monitor Prompt

When the Stat and Attn indicators are on, the ROM Monitor prompt
displays on the console terminal. Enter the boot command at the prompt.
If you did not enter a file name with the command, a prompt asks you for
one.
4.2.2.5

Set Up Mode Error States

Table 4-4 describes the state of the indicators if errors occur at different
stages of the start-up process. For example, if the CSMIM2 fails while
testing the hardware (state T2), the error condition is hardware failure
TE2. A description of each error condition follows Table 4-4.
Activity
TE2: Hardware failure
TE7: Booted wrong image
Key:
= On continuously
= Flashing regularly (about 1Hz)
4.2.2.6

Activity TE2: Hardware Failure

The ROM diagnostics detected a CSMIM2 hardware problem requiring
service. Call technical support.
4.2.2.7

Activity TE7: Booted Wrong Image

The CSMIM2 loaded an inappropriate image. Pressing the Set Up switch
approximately 3 seconds to generate a reset clears this error. The
CSMIM2 loads inappropriate images if one of the following operator
errors occurs:
Configuring the CSMIM2 with an incorrect file name, or renaming or
copying the image file to the wrong name.
Supplying the wrong name to the boot command.
CSMIM2 Installation Guide
Table 4-4 Test Mode Error Indicator States
Power-up and Boot Procedures
Stat
green
= Off
= Flashing irregularly
Attn
Traf
red
green
4-5