To measure the noise level, observe the value presented on the
dialog box.
We recommend that you do this test twice. First, do the test with all other hydroacoustic
systems (echo sounders, ADCP, sonars) turned off. Second, do the test with normal
operating conditions. This allows you to see how the other hydroacoustic systems affect
the operation and performance of your SU90 system.
Procedure
1
On the
menu, select
Main
a
Select
SU90 Factory Defaults
b
Select
Activate Selected Setting
c
Select
OK
2
On the
menu, set
Main
3
Open the
Operation
4
Open the
Active
5
Open the
Setup
6
Select
to open the dialog box.
BITE
a
Select
Noise
b
Select
Start Noise Measurements
c
On the
Active
value.
d
Note frequencies with high noise levels, and try to avoid using them.
Tip
The factory default settings include operating frequency. If you apply these settings
remember to make the appropriate changes afterwards.
Related topics
Choosing operating mode and key transmit parameters, page 50
381291/D
User Settings
.
.
to apply your changes and close the
to 1000 m.
Range
menu. Set
Tx Power
menu. Set
Pulse Type
menu.
to open the page.
menu, change the
.
User Settings
to Off.
to CW Medium.
.
setting while observing the noise
Frequency
Operating procedures
page in the
Noise
BITE
dialog box.