2
Open the cabinet door.
WARNING
High voltages are used. This equipment must be serviced only by qualified
personnel familiar with high-voltage equipment and the potential hazards
involved. Failure to observe this precaution could result in bodily injury. You
may be exposed to electric shock. Read and understand the applicable first
aid instructions related to electric shock.
3
Locate the
Hoist/Lower Switch
This is for safety reasons.
4
Lowering the transducer:
a
Locate the
b
Open the transparent plastic cover on the front of the contactor.
c
Use a small screw driver, and press the spring return actuator to apply voltage
to the motor.
d
Lower the transducer and STOP before you reach the bottom position.
5
Hoisting the transducer:
a
Locate the
b
Open the transparent plastic cover on the front of the contactor.
c
Use a small screw driver, and press the spring return actuator to apply voltage
to the motor.
d
Hoist the transducer and STOP before you reach the upper position.
6
Locate the
Hoist/Lower Switch
Note
For normal operation from the Operating Panel, the switch must be set to REMOTE.
7
Close the cabinet door.
Related topics
Lowering and hoisting the transducer from the sonar room, page 120
126
(S302). Set the switch to position STOP.
(K302) on the right side.
Lowering Contactor
(K301) on the left side.
Hoisting Contactor
(S302). Set the switch to position REMOTE.