Kongsberg Simrad SU90 Operator's Manual page 31

Hide thumbs Also See for Simrad SU90:
Table of Contents

Advertisement

A line of X'es in the vertical views shows the bottom of the purse seine. The depth
is defined for the fishing gear you have chosen. Under
to open the dialog box. For the selected purse, select a depth value. Use
Gear Setup
on the
Purse Depth
If you have connected a compatible catch monitoring system to your SU90 system,
information from these sensors are shown in the Catch view.
5
At the bottom of the SU90 presentation, select a suitable presentation mode, and
activate the Echogram view.
The Echogram view provides echo data from a horizontal beam in a common
echogram presentation. The echo data is taken from the current bearing and tilt. The
beam used to provide data is identified in the top left corner of the view. Horizontal
dotted lines show the depth intervals.
• You can change the bearing on the
line in a Horizontal view and drag it sideways.
• You can change the tilt angle by means of the
You can also click on the tilt line in a Vertical view and drag it up and down.
Left-click in the Echogram view to open the tooltip. The tooltip provides the cursor
location in the echogram (slant range, true range and depth) as well as the current
pulse duration and time.
The
Horizontal Scroll
from right towards left in the Echogram and Inspection views. The speed is
controlled by adjusting the number of pixels used to present each ping. A higher
speed will update the view faster, but will also reduce the resolution.
6
At the bottom of the SU90 presentation, select a suitable presentation mode, and
activate the Plane view.
The Plane view presents the echo data in a horizontal sector ("fan"). The sector
direction can be changed in both vertical and horizontal directions. The tilt is drawn
in the Vertical and Horizontal views as two dotted lines. The same dotted lines are
shown in the Horizontal view as a dedicated bearing line to visualize the direction
of the plane beam.
• You can change the bearing on the
dedicated dotted bearing line in a Horizontal view and drag it.
• You can change the tilt angle by means of the
The
Horizontal Tx Sector
be set to 360°.
• The selected range is divided into identical distances.
• The distance and depth of the cursor location is shown in the lower right corner
of the view.
• The current settings for range, gain and tilt are show in the lower left corner
of the view.
381291/D
menu to toggle this line On or Off.
Cosmetics
Main
function controls how fast the echo presentation shall move
Main
function defines the opening angle of the sector. It can
Fishing Gear
menu. You can also select the bearing
function on the
Tilt
menu. You can also click on the
function on the
Tilt
Getting started
, select
Fishing
menu.
Main
menu.
Main
29

Advertisement

Table of Contents
loading

Table of Contents