• Ethernet cables
It is very important that high-quality Ethernet cables are used. You must use CAT-5E
STP (Shielded Twisted Pair) quality or better.
Neither tools nor instruments are required.
Context
When supplied, the Operating Panel is set up with the following communication
parameters:
• IP Address: 157.237.60.20
• Subnet mask: 255.255.255.0
• Gateway: 157.237.60.1
The IP and MAC addresses for your Processor Unit are contained in a text file named
IPandMACaddress.txt
in the following format (example):
SU90
157.237.60.13
AC:1F:6B:1D:42:E6
Tip
If the distance between the Processor Unit and your second display is considerable, we
suggest that you use KVM (Keyboard Video Mouse) technology to preserve the video
quality.
Procedure
1
Make the following preparations.
a
On the Processor Unit, close any programs that are running, and return to
the desktop.
b
Insert the Ethernet switch between the Operating Panel and the Processor Unit.
Make sure that you use the correct Ethernet socket on the rear side of the
computer: ETH1
c
Install the secondary Operating Panel.
d
Connect the Operating Panel to AC mains.
e
Connect the power cable from the Ethernet switch to the AC power outlet.
f
Do not connect the Operating Panel to the Ethernet switch.
381291/D
. The file contains the product name, IP address and MAC address
Maintenance procedures
161