Table of Contents
Table of Contents
5
About this Manual
11
Simrad Su90
13
Important
13
System Description
15
System Diagram
17
General Safety Rules
18
Support Information
18
Getting Started
21
Operating Panel Description
22
Starting Normal Operation
25
Turning on the SU90 System for Normal Use
25
Getting to Know the User Interface
26
Getting to Know Presentation Modes and Views
28
Selecting Normal Mode to Start Pinging
32
Adjusting the Radius of the Search Area
33
Adjusting the Echo Sensitivity
34
Changing the Vertical Angle of the Sonar Beams
36
Adjusting the Horizontal Direction of the Sonar Beam
38
Turning off the SU90 System
40
Basic Operating Procedures
41
Selecting the Language Displayed in the Menus and Dialog Boxes
41
Selecting Operating Frequency for Minimum Noise
42
Hiding the Menu System When You Do Not Need It
43
Saving Single or Sequential Screen Captures
43
Saving the Current User Settings
45
Defining the Ping (Transmission) Modes
46
Open the
46
Operating Procedures
48
Getting Started
49
Turning on the SU90 System
49
Lowering and Hoisting the Transducer from the User Interface
50
Turning off the SU90 System
51
Choosing Operating Mode and Key Transmit Parameters
52
Selecting Normal Mode to Start Pinging
52
Selecting Replay Mode
53
Selecting Inactive Mode
54
Setting up the SU90 System for Maximum Echo Refresh Rate
55
Transmitting Single Pings
56
Transmitting with Fixed-Time Intervals
56
Related Topics
56
Use Transmission Mode to Control How Often the
56
SU90 System Shall Transmit Its Energy into the Water
56
For Normal Use, Choose Maximum. if You Choose
56
Maximum, the SU90 System will Transmit (Ping)
56
Continuously and as Often as Possible
56
Open the Operation Menu
56
Set Operation to Normal
56
Adjusting the Output Power to Match Varying Conditions
57
Related Topics
57
Selecting the Best Operating Frequency
58
Controlling the Gain and Range Settings
60
Adjusting the Gain (Echo Sensitivity)
60
Adjusting the TVG (Time Variable Gain) Setting
62
Adjusting the Sonar Range
62
Expanding the Range Within the Sonar View
64
Adjusting the Intensity of the Echo Presentations
65
Changing the Tilt
65
Adjusting the Bearing
67
Using the Markers and Tracking Features
70
Starting a Position Track
70
Starting a Target Track
71
Placing a New Marker
72
Deleting a Marker
73
Measuring the Size of a School Relative to the Purse seine
74
Using Visual Aids During the Purse seine Catch Phase
74
Selecting a Geographical Area for Accurate Target Tracking
76
Defining the Physical Size of the Tracking Area
77
Choosing the Fishing Gear in Use
78
Changing the Fishing Gear Properties to Match Your Own Equipment
79
Improving the Recognition of Fish and Schools Using Receiver Filters
80
About the Receiver Filter Sequence in the SU90 System
80
Reducing Noise and Reverberation with the AGC (Automatic Gain Control) Function
81
Reducing Propeller Noise and Interference with the Noise Filter
82
Reducing Bottom and Surface Reverberation with the RCG (Reverberation Controlled Gain) Function
83
Reducing Bottom and Surface Reverberation with the RCG
83
Reducing Noise and False Echoes with the Ping-Ping Filter
85
Reducing the Strong Bottom Echo to See Fish Close to the Seabed
86
Adjusting the Intensity of the Echo Presentations
86
Recording and Replaying Echo Data
88
Defining the File and Folder Settings for Data Recording
88
Recording Echo Data
89
Accessing the Echo Data Files to Delete, Move or Copy Them
90
Selecting Replay Mode
91
Choosing Which Echo Data File(S) to Replay
92
Setting up Presentation Modes and Views
94
Moving a View to Another Display
94
Rearranging the Layout of the Echo Presentations
95
Restoring the Locations and Sizes of the Views
96
Defining Settings Related to User Preferences and Individual Customizing
97
Selecting Menu Language
97
Hiding the Menu System
98
Placing the Menu on the Left Side of the Display Presentation
99
Selecting the Information to Appear on the Top Bar
99
Enabling Coordinated Universal Time (UTC) on the Bottom Bar
100
Selecting Which Tooltips to Appear in the User Interface
101
Adjusting the Backlight Intensity on the Operating Panel
101
Reducing the Light Emitted from the Display Presentation
102
Increasing the Visibility of the Information Panes
103
Changing the Colour Palette ("Skin") Used in the Display Presentations
103
Choosing the Colours Used to Present the Echoes
104
Selecting Measurement Units
105
Configuring the Environmental Parameters
105
Setting up the Alarm Limits for System Protection
106
Defining the Middle Position of the Transducer
107
Saving, Retrieving and Handling User Settings
110
Saving the Current User Settings
110
Choosing Previously Saved User Settings
111
Renaming Existing User Settings
112
Deleting User Settings that Are no Longer Used
113
Choosing Factory Default Settings
114
Defining the User-Selected Features on the Operating Panel
115
Selecting Which Operating Panel to Use
115
Assigning User Settings or Presentation Modes to the Operating Panel
116
Assigning Functions to the Rotary Switches on the Operating Panel
118
Assigning Functions to F1, F2 and F3 on the Operating Panel
119
Maintenance Procedures
121
Lowering and Hoisting the Transducer from the Sonar Room
122
Lowering and Hoisting the Transducer Using the Hoist/Lower Switch
123
Lowering and Hoisting the Transducer Using the Hand Crank
125
Emergency Lowering and Hoisting Using the Two Contactors
127
Setting up the Interfaces to Peripheral Devices
129
Installing Navigation Sensors and Other Sensors
129
Defining the Serial and Ethernet (LAN) Port Parameters
130
Setting up the Input from a Navigation System (GPS)
132
Setting up the Interface for Speed Log Input
134
Setting up the Interface for Course Gyro Input
136
Configuring the Sensor Interface
139
Setting up the Input from a Motion Reference Unit (MRU)
140
Setting up the SU90 System for Synchronized Operation
142
Inserting the Installation Parameters
145
Inserting the Ship Origin and Dimensions
145
Inserting the Installation Parameters for the Transducer
147
Inserting the Installation Parameters for the Motion Reference Unit (MRU)
150
Adjusting the Built-In Motion Sensor Offset
152
Installing and Maintaining Software
155
Installing the Operating Software
155
Removing the Operating Software
156
Obtaining and Installing a Software License for Additional Functionality
157
Setting up the Operating Panel (Mk2)
159
Using more than One Operating Panel to Control the Sonar (Mk2)
162
Using a Single Operating Panel to Control more than One Sonar (Mk2)
166
Updating the Operating Panel Support Applications (Mk2)
170
Updating the Firmware on the Operating Panel (Mk2)
171
Testing the Noise Conditions and the Sonar Functionality
174
Checking the Status of the Transceiver Boards
174
Checking the Transducer by Means of the Diagnostics Functionality
176
Measuring the Noise in Passive Mode
179
Making a Noise/Speed Curve to Determine Vessel Noise
180
Measuring Flow Noise
184
Preventive Maintenance
188
Preventive Maintenance Schedule
189
Related Topics
190
Requirements for Personnel and Tools
191
Approved Anti-Fouling Paints
191
Checking the Environmental Conditions in the Sonar Room
193
Inspecting and Cleaning the Display
193
Inspecting and Cleaning the Processor Unit
194
Inspecting and Cleaning the Operating Panel
194
Inspecting and Cleaning the Transceiver Unit
195
Visual Inspection of the Hull Unit
196
Inspecting and Cleaning the Transducer Face
197
Painting the Transducer Face
198
Inspecting and Replacing Sacrificial Anodes
200
Lubricating the Hoisting Spindle
201
Lubricating the Transducer Shaft Sleeve
202
Inspecting and Cleaning the Heat Exchanger
204
Environmental Requirements
206
Menu System
209
About the Menus and Menu Buttons
210
Using the "Smart" Menu Buttons
211
Main Menu
213
Operation Menu
215
Display Menu
217
Setup Menu
220
Active Menu
224
Objects Menu
227
Visual Objects Menu
231
Cosmetics Menu
234
Shortcut Menus
236
Advertisement
Kongsberg Simrad SU90 Series Technical Specifications (114 pages)
Brand:
Kongsberg
| Category:
Marine Equipment
| Size: 7.29 MB
Table of Contents
Table of Contents
5
Simrad Su90
9
Important
10
System Description
12
System Diagram
14
System Units
15
Display Description
15
Processor Unit Description
16
Transceiver Unit Description
17
Hull Unit Description
18
Transducer Description
19
Installation Trunk Description
21
Additional Required and Optional Items
22
Installation Trunk Requirement
22
Speed Log Requirement
23
Course Gyro Requirement
23
Uninterruptible Power Supply (UPS) Requirement
23
Operating Panel Option
24
Global Positioning System (GPS) Option
24
Scope of Supply
26
Order Information
27
General Safety Rules
28
Installation Requirements
30
Supply Voltage Requirements
30
Uninterruptible Power Supply (UPS) Requirements
30
Cables and Wiring Requirements
31
Compass Deviation Requirements
31
Noise Sources
31
Dry Docking Requirements
32
Requirement for Classification Approval
32
Network Security
33
Support Information
34
Technical Specifications
37
Introduction to Technical Specifications
38
Performance Specifications
38
Power Requirements
43
Display Power Requirements
43
Operating Panel Power Requirements (Mk1)
43
Operating Panel Power Requirements (Mk2)
44
Operating Panel Power Requirements (Mk3)
44
Transceiver Unit Power Requirements
44
Hull Unit Power Requirements
45
Weights and Outline Dimensions
46
Display Weight and Outline Dimensions
46
Operating Panel Weight and Outline Dimensions (Mk1)
46
Operating Panel Weight and Outline Dimensions (Mk2)
47
Operating Panel Weight and Outline Dimensions (Mk3)
47
Transceiver Unit Weight and Outline Dimensions
47
Outline Dimensions
47
Hull Unit Weight and Outline Dimensions
48
Environmental Requirements
50
Display Environmental Requirements
50
Operating Panel Environmental Requirements (Mk1)
50
Operating Panel Environmental Requirements (Mk2)
51
Operating Panel Environmental Requirements (Mk3)
51
Transceiver Unit Environmental Requirements
51
Hull Unit Environmental Requirements
52
Compass Safe Distance
53
Display Compass Safe Distance
53
Operating Panel Compass Safe Distance (Mk1)
53
Operating Panel Compass Safe Distance (Mk2)
54
Operating Panel Compass Safe Distance (Mk3)
54
Transceiver Unit Compass Safe Distance
54
Hull Unit Compass Safe Distance
54
Minimum Display Requirements
55
Drawing File
56
About the Drawings in the Drawing File
57
494024 Processor Unit Outline Dimensions (HT20470/DC)
58
494025 Processor Unit Outline Dimensions (HT20470/AC)
61
204688 Operating Panel Dimensions (Mk1)
64
443179 Operating Panel Dimensions (Mk2)
66
440689 Operating Panel Cut-Out Drawing (Mk2)
69
439594 Operating Panel Adapter Plate (Mk2)
70
476352 Operating Panel Dimensions (Mk3)
72
489582 Transceiver Dimensions (Mk2)
75
381457 Transceiver Dimensions (Mk1/Old)
78
379507 Hull Unit Dimensions SU92
81
379506 Hull Unit Dimensions SU93
84
411053 Hull Unit Dimensions SU94
87
372751 Installation Trunk Dimensions
90
374676 Installation Trunk Extender (180 MM)
93
207485 Blind Flange Dimensions (Ø760 MM)
96
082973 Mounting Flange DN500
97
083045 Gate Valve Installation DN500
100
33498 Gate Valve Dimensions DN500
102
37357 Gate Valve Dimensions DN500
105
Datagram Formats
108
Kongsberg Simrad SU90 Series Manual (64 pages)
Brand:
Kongsberg
| Category:
Marine Equipment
| Size: 1.15 MB
Table of Contents
Table of Contents
3
Introduction
5
Purpose
6
Personnel and Location
6
Referenced Documents
6
Tools and Test Equipment
7
Acceptance Test Summary
8
Hardware and Software Registration
9
Verification of Previously Tested Items
10
Software Items
11
Hardware Items
12
Display
12
Processor Unit
12
Transceiver Unit
13
Operating Panel
14
Hull Unit Controller
15
Hull Unit
15
Transducer
16
Test Procedures
17
Inspecting the Installation of the SU90 System
18
Visual Inspection of the Display
18
Visual Inspection of the Processor Unit
20
Visual Inspection of the Operating Panel
21
Visual Inspection of the Transceiver Unit
23
Visual Inspection of the Hull Unit Controller
24
Checking the Environmental Conditions in the Sonar Room
26
Making Sure that All SU90 System Cables Are Properly Connected
27
Testing the Operating Functionality of the SU90 System
29
Checking the Hull Unit Lowering and Hoisting Functionality
30
Testing the User Interface to Verify Basic Functionality
35
Verifying System Operation by Means of the Element BITE Functionality
36
Testing the Interfaces with Peripheral Devices
41
Verifying the Communication with a Navigation System (GPS)
41
Verifying the Communication with Speed Log
43
Verifying the Communication with the Course Gyro
45
Verifying the Communication with the Motion Reference Unit (MRU)
47
Verifying the Installation Parameters
50
Verifying Vessel Origin and Ship Dimensions
50
Verifying the Installation Parameters for the Transducer
52
Verifying the Installation Parameters for the Global Positioning System (GPS) Antenna
54
Verifying the Installation Parameters for the Motion Reference Unit (MRU)
55
Customer Acceptance Form
58
Secondary Procedures
59
Setting up the Operating Panel (Mk2)
59
Advertisement
Kongsberg Simrad SU90 Series Manual (34 pages)
Fish-finding sonar
Brand:
Kongsberg
| Category:
Sonar
| Size: 0.83 MB
Table of Contents
Table of Contents
3
Software Changes
5
Do I Need to Upgrade
7
Software Licenses
8
Software Installation
9
Removing the Operating Software
9
Installing a New Version of the Operating Software
11
Settings You Need to Restore after a Software Upgrade
12
End-User Documentation
13
Updated Functions and Dialog Boxes
14
User Settings Setup Page
14
Units Page
15
New Marker Dialog Box
17
Operating Panel Page
17
Operating Panel Mk2
19
Operating Panel Mk3
23
Display Options Dialog Box
26
General Page
26
Minimum Display Requirements
30
Kongsberg Simrad SU90 Series Replacement Procedure (14 pages)
Brand:
Kongsberg
| Category:
Transducer
| Size: 0.46 MB
Table of Contents
Table of Contents
3
About this Document
5
Logistics
6
Personnel Requirements
6
Required Tools for Transducer Replacement
6
Procedures
8
Replacing the Transducer
8
Transducer Replacement Introduction
8
Relevant Spare Parts
9
Unpacking a New Transducer
9
Dismounting the Transducer from the Bottom of the Transducer Shaft
10
Mounting a New Transducer to the Bottom of the Transducer Shaft
11
Replacing the Zinc Anodes
12
Advertisement
Related Products
Kongsberg Simrad SP90 Series
Kongsberg Simrad SX90 Series
Kongsberg Simrad C-All
Kongsberg SBP 120
Kongsberg SR 723
Kongsberg SR 742
Kongsberg SV 650
Kongsberg Simrad SP60
Kongsberg Simrad SP70
Kongsberg SV Series
Kongsberg Categories
Marine Equipment
Sonar
Marine Radio
Transceiver
Radio
More Kongsberg Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL