Kongsberg Simrad SU90 Operator's Manual page 182

Hide thumbs Also See for Simrad SU90:
Table of Contents

Advertisement

Simrad SU90 Operator Manual
2
Set
Tx Power
c
Open the
Active
1
Set
TVG
2
Set
Ping-Ping Filter
3
Set
Pulse Type
4
Set
Frequency
5
Set
Horizontal TX Sector
6
Set
Vertical TX Sector
7
Set
AGC
8
Set
RCG
9
Set
Noise Filter
d
Open the
Setup
e
Open the
BITE
f
Select
Noise
g
Select
Start Noise Measurements
5
Repeat for each vessel speed and operating frequency.
a
Ask the bridge to set the speed.
b
If possible, verify the vessel speed on the top bar.
c
Read the noise value from the noise circle.
d
Record the values in the result table.
e
Repeat for every 2 kHz up to and including 30 kHz.
1
Increase the operating frequency with 2 KHz.
2
Read the noise value from the noise circle.
3
Record the values in the result table.
f
Ask the bridge to set the next speed.
6
When all the measurements have been made, type the data (speed and noise) into a
spreadsheet to create the curve.
7
Hoist the transducer to its upper position.
8
Close the
BITE
180
to Off.
menu.
(Time Variable Gain) to 0 log R.
to Off.
to CW Short.
to 20 kHz.
to Omni.
to Normal.
(Automatic Gain Control) to Off.
(Reverberation Controlled Gain) to 0 (zero).
to Off.
menu.
(Built-In Test Equipment) dialog box.
to open the page.
(Built In Test Equipment) dialog box.
.
381291/D