Panasonic Switch-M16eGi Operation Manual page 97

Hide thumbs Also See for Switch-M16eGi:
Table of Contents

Advertisement

4.6.7.f. Set IPv6 Syslog Server
On the System Transmission Configuration Menu, pressing "P" opens the Set
IPv6 Syslog Server screen, as shown in Fig. 4-6-30. On this screen, you can
configure the setting of the Syslog server to which a system log Is sent.
PN28160i Local Management System
System Security Configuration -> Set IPv6 Syslog Server Menu
Syslog Server List:
No.
IPv6 Address
---- ----------------------------------------
1
::
2
::
-------------------------------- <COMMAND> -----------------------------------
Set Server [I]Pv6
[Q]uit to previous menu
Command>
Enter the character in square brackets to select option
Screen Description
Server IPv6
Shows the IPv6 address of Syslog server. :: is displayed because no
Address:
address is set on shipment.
Available commands are listed below.
I
Set an IPv6 address of Syslog server.
Press "I." The command prompt changes to " Enter manager entry number>." Enter a
Syslog server entry number between 1 and 2. The command prompt changes to "
Enter new server IPv6 address>." Enter the IPv6 address of the Syslog server.
Q
Return to the previous menu.
Fig. 4-6-30 Syslog Configuration
97

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pn28160i-idPn28160i-thPn28160i-myPn28160i-sgPn28160i

Table of Contents