Panasonic Switch-M8eGi Series Installation Manual

Hide thumbs Also See for Switch-M8eGi Series:

Advertisement

Quick Links

Installation Guide

 Thank you for purchasing our product.
 This document provides important information about safe and proper
operations of this Switching Hub.
 Please read the "Important Safety Instructions" on pages from 3 to 5.
 Any problems or damage resulting from disassembly of this Switching Hub
by customers are not covered by the warranty.
2-12-7, Higashi-Shimbashi, Minato-ku, Tokyo Japan, 105-0021
©
Switch-M8eGi
Model No.
2019
I0818- 11019
PN28080i-TH
PN28080i-MY
PN28080i-ID
PN28080i-SG
Printed in Japan

Advertisement

Table of Contents
loading

Summary of Contents for Panasonic Switch-M8eGi Series

  • Page 1: Installation Guide

    Switch-M8eGi Installation Guide PN28080i-TH Model No. PN28080i-MY PN28080i-ID PN28080i-SG  Thank you for purchasing our product.  This document provides important information about safe and proper operations of this Switching Hub.  Please read the "Important Safety Instructions" on pages from 3 to 5. ...
  • Page 2: Table Of Contents

    Contents Important Safety Instructions Basic Instructions for the Use of This Product 1 Product Outline 1.1 Features 1.2 Specifications 1.3 Accessories 1.4 Basic operation 2 Part Names and Functions 2.1 LED display change 3 Installation and Configuration 3.1 Grounding Cable Connection 3.2 Mounting on a wall 3.3 Mounting to rack 3.4 Configuration of IP address (Basic)
  • Page 3: Important Safety Instructions

    Important Safety Instructions This chapter contains important safety instructions for preventing bodily injury and/or property damage. You are required to follow them.  Severity of bodily injury and/or property damage, which could result from incorrect use of the Switching Hub, are explained below. WARNING This symbol indicates a potential hazard that could result in serious injury or death.
  • Page 4 WARNING Do not put the Switching Hub into fire.  Deviation could lead to explosion and/or fire.  If the device is going to be used in high temperature environments, do not perform the following operations with bare hands. - Relocating the installation area, transporting, and attaching, and removing attachment brackets, etc.
  • Page 5 CAUTION  Up to two Switching Hubs can be connected. When connecting two Switching Hubs, use connection brackets and screws (for fixing the connection brackets) supplied with 19-inch rack mount brackets (two coupled units)( PN71052, optional) to securely fix the connection brackets to the connection screw holes on the front and back panels, and then install the Switching Hubs.
  • Page 6: Basic Instructions For The Use Of This Product

     When using two Switching Hubs, do not stack them. When you place them side by side, allow for a space of 20 mm or more between them. 1. Please note that Panasonic shall not bear any liability whatsoever for any damages (this shall include lost earnings, lost opportunities, etc. but this is not restricted to these...
  • Page 7: Product Outline

    Product Outline Switch-M8eGi is an all Giga bit Ethernet Switching Hub with management function having 8 ports of 10/100/1000BASE-T and two pairs of 10/100/1000BASE-T port and SFP extension slot, one of which is selectable. 1.1 Features  Has wire speed layer 2 switching functions. ...
  • Page 8: Specifications

    Product Outline 1.2 Specifications Twisted pair port 1-8:RJ45 connecter Interface Transmitting and receiving network system IEEE 802.3 10BASE-T IEEE 802.3u 100BASE-TX IEEE 802.3ab 1000BASE-T Energy Efficient Ethernet function IEEE 802.3az(LPI) SFP extension slot port 9 Transmitting and receiving network system IEEE 802.3z 1000BASE-X Note: Can be used as an SFP exclusively...
  • Page 9: Accessories

    1.3 Accessories Please be sure to confirm the content. Please contact our distributor if any of the contents are insufficient. Quantity  Installation Guide (this document)  CD-ROM (PDF version of Operating Instructions, ZEQUO assist Plus)  Rubber foot  Wall mount bracket ...
  • Page 10: Part Names And Functions

    Part Names and Functions Power cord hook block MAC address label Back panel LED display change button 10/100/1000BASE-T port Front panel Enlarged view on the next page Console port (RJ45) SFP extension slot Explanation label  Power port Connect the supplied power cord to this port and connect the other end into an electric outlet.
  • Page 11 Power LED Collision LED Status/ECO mode LED LED display change GIGA mode LED button Speed modeLED DUPLEX mode LED Loop History mode LED  POWER (Power) LED Green Light : Power is ON. : Power is OFF.  ANY/COL. (Collision) LED Orange Light : During half-duplex operation, packet collision is occurring in either port.
  • Page 12 Part Names and Functions Table1. Ports and Port LED lamps 1 to 9 correspond as shown below. Port LED Display mode Behavior Description STATUS/ECO Green Light Link is established. Green Blink Transmitting and receiving data. No device connected. Green Light Link is established at 1000 Mbps.
  • Page 13: Led Display Change

    2.1 LED display change ●Display style set by the LED display change button Indication on the front panel and LED lamps LED display change button You can display the following items using the LED display switch button. Display for the connection with a connected terminal (Status mode),Display for the 1000 Mbps transmission rate (GIGA mode),Display for the 100Mbps or 10 Mbps transmission rate (Speed mode),Display for the full-duplex or half-duplex transmission system (DUPLEX mode),Display for ports with a loop history (Loop...
  • Page 14 Part Names and Functions Switch two types of Base modes and their LEDs in the following way: When Base mode is Status mode (factory default setting) Press "LED DISPLAY CHANGE BUTTON" manually. Automatic Boot Automatically returns to Base mode after 1 minute. Status mode DUPLEX Loop History...
  • Page 15: Installation And Configuration

    Installation and Configuration 3.1 Grounding Cable Connection The chassis of the equipment must be grounded properly so that the lightning can flow to the ground, which improves the capability of the chassis for resisting the electromagnetic interference. 1. Ensure that the grounding cable is connected correctly so that the equipment is protected against lightning and interference.
  • Page 16: Mounting On A Wall

    Installation and Configuration 3.2 Mounting on a wall Use the two wall mount brackets and eight screws (for fixing the wall mount brackets to the Switching Hub) supplied with the mount brackets PN71053 to fix the mount brackets to the four holes on each side of the Switching Hub.
  • Page 17: Mounting To Rack

    3.3 Mounting to rack Use the two 19-inch rack mount brackets and eight screws (for fixing the rack mount brackets to the Switching Hub) supplied with the mount brackets PN71051 (optional) to fix the mount brackets to the four holes on each side of the Switching Hub. Then securely install the Switching Hub onto the rack using the four screws (for a 19-inch rack mount) supplied with the mount brackets PN71051 (optional) or the screws supplied with the rack.
  • Page 18: Configuration Of Ip Address (Basic)

    Installation and Configuration 3.4 Configuration of IP address (Basic) (1) Connect this Switching Hub and PC with a RJ45–DSub 9-pin console cable and start up the terminal emulator (hyper terminal, etc.). (2) Pressing Enter key 3 times opens Login screen. Enter Login name and Password (the default is "manager"...
  • Page 19 Screen 1 Screen 2 Screen 3 Screen 4 Screen 5 * For the following, please see the PDF version Operating Instructions in CD-ROM. - Detailed configuration and management methods using CLI/WEB. - Configuration and management method from ZEQUO assist Plus.
  • Page 20: Troubleshooting

    Troubleshooting If you find any problem, please take the following steps to check.  LED The POWER LED (Power) is not lit.  Check if the power cord is disconnected. Please confirm that the power cord is securely connected to the power port. ...