Thank you very much for purchasing Panasonic products. Read this Instruction
Manual carefully and thoroughly for the correct and optimum use of this product.
Kindly keep this manual in a convenient place for quick reference.
● Never use this product in a device for personnel protection.
● In case of using devices for personnel protection, use products which meet laws and standards,
such as OSHA, ANSI or IEC etc., for personnel protection applicable in each region or country.
● Do not use this product as a device for emergency stop.
● This product is used to start up the machinery. Securing safety for the start-
up of machinery should be performed separately.
● When using the products for two-hand control, comply with the following contents.
• Select a model of a control device for two-hand control, based on results of risk assessment.
• Make sure to use a controller for two-hand control which complies with
ISO 13851 (EN 574.)
• For another requirements such as mounting of this product, or prevention of
accidental actuation and of defeat etc., comply with ISO 13851 (EN 574, JIS
B 9712) and ANSI B11.1, B11.9. Furthermore, comply with the regulations es-
tablished by national or regional security committees (Occupational Safety and
Health Administration: OSHA, the European Standardization Committee, etc.)
1
OUTLINE
● This product is an optical touch switch which detects a hand
by a thru-beam type photoelectric sensor.
● When a hand is touched to the sensing surface, output turns
ON or OFF.
2

FUNCTIONAL DESCRIPTION

4. External input
indicator 1
6. Sensing
(Green)
surface
5. External
input
indicator 2
(Orange)
8. B side terminal
block
Designation
Operation indicator
1
Lights up when an object is detected.
× 2 (Green)
Power indicator
2
Lights up when the power is ON.
(Green)
Blinks or lights up when fault occurs.
Fault indicator
3
Refer to "
(Yellow)
ing operation.
External input indi-
Lights up when external input 1 is valid.
4
cator 1 × 3 (Green)
Refer to "
External input indica-
Lights up when external input 2 is valid.
5
tor 2 × 4 (Orange)
Refer to "
Thru-beam type photoelectric sensor is incorporated in the sensing
6
Sensing surface
surface. Thus, when the light beam is interrupted by fingers, the sensor
goes into the beam interrupted condition and output turns ON or OFF.
7
A side terminal block Connects +V, output 1, 2 and 0V.
Connects switching terminals of time-out function, output
8
B side terminal block
3, and external input 1, 2.
3
MOUNTING
● Follow the procedures below when mounting this product on a mounting plate.
Procedures
1. Drill a hole in a mounting plate (thickness: 3mm or less.)
Dimensions of a mounting hole
to be drilled when mounting on
a resin plate (Unit: mm)
+0.2
4.8
0
+0.5
33
0
+0.5
ø30.5
0
INSTRUCTION MANUAL
SW-101
MJE-SW101 No.0055-94V
WARNING
3. Fault indicator
2. Power indicator
(Yellow)
1. Operation indicator
1. Operation indicator
(Green)
5. External input
5. External input
indicator 2
indicator 2
(Orange)
(Orange)
4. External input
4. External input
indicator 1
indicator 1
(Green)
(Green)
7. A side terminal
block
Function
TROUBLESHOOTING" for details in blink-
FUNCTIONS" for details.
FUNCTIONS" for details.
Dimensions of a mounting hole
to be drilled when mounting on
a metal plate (Unit: mm)
4.8
+0.5
ø30.5
0
R4±0.1
+0.5
18.4
0
<Bottom of the product (Unit: mm)>
M30 × 1.5
2. Make sure to fit a mounting packing (ac-
cessory) to the terminal area of the main
body first, then put the main body into the
mounting plate. (Note 1)
<Fitting diagram of the mounting packing>
3. Fasten a mounting nut (accessory) from
the reverse side of the mounting plate.
(Note 2)
The tightening torque should be 2 to
3N·m.
Notes: 1) Make sure to use the mounting packing (accessory), or waterproof property will be
invalid.
2) A mounting tool SW-MT1 for fastening the mounting nut is available separately.
The shape of fastening part of SW-MT1 is M10 nut.
3) When using the products for two-hand control, be sure to mount the products by
complying with ISO 13851 (EN 574, JIS B 9712) and ANSI B11.1, B11.9. In ad-
dition, be sure to use a controller for two-hand control which complies with ISO
13851 (EN 574, JIS B 9712).
4
I/O CIRCUIT DIAGRAMS
<In case of Minus Common>
(Green)
(Green)
External input
indicator 1
External input
indicator 2
<In case of Plus Common>
+0.2
External input
0
indicator 1
External input
+0.5
33
indicator 2
0
+0.5
10.2
0
*1
R4±0.1
Non-voltage contact or NPN open-collector transistor, PNP open-collector transistor
0 to 1V or 10V to +V: Valid (External input indicator lights up )
4 to 6V or Open: Invalid (External input indicator turns OFF)
80
80
Mounting packing
(Accessory)
Mounting packing
(Accessory)
Terminal No.
+V
Switching terminal of
time-out function (+V)
Switching terminal of
time-out function (IN)
Output 1_1
Output 1_2
Output 2_1
Output 2_2
Output 3_1
Output 3_2
0V
External input
External input 1
circuit 1
External input 2
External input
circuit 2
Internal circuit
Users' circuit
Terminal No.
+V
Switching terminal of
time-out function (+V)
Switching terminal of
time-out function (IN)
Output 1_1
Load
Output 1_2
Output 2_1
Load
Output 2_2
Output 3_1
Load
Output 3_2
0V
External input 1
External input
circuit 1
External input
External input 2
circuit 2
Internal circuit
Users' circuit
or
or
Main body
Mounting
Mounting nut
(Accessory)
plate
Mounting tool
SW-MT1
(Optional)
Load
+
12 to 24V DC
±10%
-
Load
Load
*1
+
12 to 24V DC
±10%
-
*1

Advertisement

loading

Summary of Contents for Panasonic SW-101

  • Page 1: Functional Description

    <Bottom of the product (Unit: mm)> INSTRUCTION MANUAL Optical Touch Switch SW-101 M30 × 1.5 MJE-SW101 No.0055-94V Thank you very much for purchasing Panasonic products. Read this Instruction 2. Make sure to fit a mounting packing (ac- Manual carefully and thoroughly for the correct and optimum use of this product. cessory) to the terminal area of the main Kindly keep this manual in a convenient place for quick reference. body first, then put the main body into the mounting plate. (Note 1) WARNING <Fitting diagram of the mounting packing> Main body Mounting packing ● Never use this product in a device for personnel protection. (Accessory) Mounting packing ●...
  • Page 2: Specifications

    Switching terminal of time- SPECIFICATIONS Timer (+V) out function (+V) Switching terminal of time- Designation Optical touch switch Timer (IN) out function (IN) Item Model No. SW-101 Output 3_1 CSA 22.2 No.14, CSA 22.2 No.0.8, ANSI/NFPA 79, UL 508, Output 3 Applicable standard EN 60947-5-2 (EMC only) Output 3_2 Sensing method Thru-beam type photoelectric sensor (2 beam axes) IN2 (Orange) External input 2 Terminal No.12 has Supply voltage 12 to 24V DC±10%, Ripple P-P10% or less...