Description
General Functions
Alarm silence, 0--Auto only
(NFPA 110), 1--Always
Aux. inputs 0--5 VDC, 1 analog
Aux. inputs 0--5 VDC, 1 analog
Auxiliary inputs, up to 3 digital
(2 additional digital inputs
available with I/O module
option)
Auxiliary inputs, up to 3 digital
(2 additional digital inputs
available with I/O module
option)
Backup parameters loaded
Battery charger fault *
Chicago code active *
Common fault
Common warning
Default parameters loaded
Emergency stop
Engine cooldown (delay)
active
Engine start delay active
Engine started
Engine stopped
EPS supplying load
File system error (controller
fault)
Generator running
Input/output (optional module
board) communication loss
Internal failure
Measurement Units,
0--English, 1--Metric
Metering communication loss
NFPA 110 alarm active
Not in auto (master control
buttons)
Prime power application,
0--Standby, 1--Prime
Remote start
System ready
System timer failed
Generator Functions
AC sensing loss
AC sensing loss
Alternator protection
Ground fault input *
kW overload
Locked rotor (failed to crank)
Overfrequency
24
Section 1 Specifications and Features
Controller Display
Alarm
Message
Horn
AlarmSilenceMode
Aux Input Warning
On
Aux Input Shutdwn
On
Aux Input Warning
On
Aux Input Shutdwn
On
Backup Pars Status
Batt Chg Flt Warning
On
Auto Locked Notice
Common Fault
On
Shutdwn
Common Warng
On
Default Pars Warning
On
Emerg Stop Shutdwn
On
Eng Cooldown Notice
Start Delay Notice
Engine Start Status
Engine Stop Status
Emerg Pwr On Notice
File Error Shutdwn
On
Gen Running Notice
OB1 Com Loss
On
Intern Error Shutdwn
On
Measurement Display
MeterCommLos
On
Shutdwn
NFPA Alarm Notice
Not In Auto Warning
On
Power Type
Remote Start Status
System Ready Status
Timer Error Notice
AC Sens Loss
On
Warning
AC Sens Loss
On
Shutdwn
Alt Protect Shutdwn
On
Ground Fault Warning
On
Total Power High
On
Shutdwn
Locked Rotor Shutdwn
On
Freq High Shutdwn
On
GenSet
Fault
Write
Mode
Lamp
Access
Always
Warning
Display
Running
Shutdown
SiteTech
Stopped
S
A
W
S
W
S
W
S
W
W
S
S
W
S
DS
A
S
W
DS
A
W
S
S
W
S
S
S
A
S
Time
Delay
Range
Default
Range
Setting
Selection
(sec.)
0--1
1
0--100%
100%
0--10
0--100%
100%
0--10
0--10
(0--30
inhibit)
0--10
(0--30
inhibit)
0--1
1
0--1
0
Fixed
102%
standby,
Fixed
Fixed
112%
prime
1--5
102--140%
110%
Fixed
TP-6694 7/11
Default
Time
Delay
(sec.)
0
0
0 (0
inhibit)
0 (0
inhibit)
3
60
5
10