Download Print this page
Kohler Decision-Maker 3500 Installation Instructions

Kohler Decision-Maker 3500 Installation Instructions

Advertisement

Quick Links

Original Issue Date: 11/14
Model: 33- -150 kW Generator Sets
Market: Marine
Subject: Decision-Makerr 3500 Controller Service Replacement Kit GM92086
Introduction
The controller service replacement kit is available to
replace a non-functional controller. Use the following
procedure to install the replacement controller. See
Figure 1 for controller identification. For features and
operation of the controller, see the operation manual
(TP-6861).
1. Mini USB connection
Figure 1 Decision-Makerr 3500 Controller
Note: Do not use this controller replacement installation
instruction for upgrading software.
When replacing the controller, the following data must
be resident for the controller to function. Controller
service replacement kits do not include the three files
installed at the factory. The service technician must
install the following three files into the replacement
controller.
Application program contains the software that
D
controls system operation. The application file was
preprogrammed in the original controller at the
factory.
INSTALLATION INSTRUCTIONS
1
Personality profile is specific to the engine and
D
alternator and was preprogrammed in the original
controller at the factory.
A backup disk of the personality profile and
application program is supplied with the literature
packet shipped with the generator set. Typically, the
distributor stores this disk for possible future use such
as controller replacement or other circumstances
requiring a backup.
Note: If the personality disk is NOT available, request
a replacement from Kohler Co. using the
generator set serial number or order number.
User parameters unique to an installation include
D
timer values, setpoints, generator set data such as
voltage and
input/output selections.
parameters are typically set up for or by the installer at
the time of installation. User parameters are typically
recorded on the personality profile disk, a separate
backup disk/drive, or written on a paper form.
Note: If the user parameters are included on the
personality disk, the disk label should indicate
Site Program—Yes.
Read the entire installation procedure. Perform the
steps in the order shown.
Always observe applicable local and national electrical
codes.
Note: The following service kit procedure changes only
the controller.
If the generator set requires
voltage
reconnection
adjustment,
see
(TP-6862).
TT-1638
11/14
These
and/or
frequency
the
installation
manual

Advertisement

loading

Summary of Contents for Kohler Decision-Maker 3500

  • Page 1 Note: If the personality disk is NOT available, request a replacement from Kohler Co. using the generator set serial number or order number. User parameters unique to an installation include timer values, setpoints, generator set data such as voltage and input/output selections.
  • Page 2 SiteTecht Software Version 3.6 or higher from the servicing the equipment. Never contact electrical leads or Kohler Power Resource Center website using the appliances when standing in water or on wet ground because TechTools button to download on your PC hard drive these conditions increase the risk of electrocution.
  • Page 3 Disconnect the generator set engine starting Reconnect the electrical connections battery(ies), negative (--) lead first. and install the replacement controller. Disconnect the generator set from load by Reconnect all of the electrical connections opening the line circuit breaker. disconnected in step 3.3. Align the controller panel with the mounting Remove the existing controller and holes and install four screws.
  • Page 4 Controller assembly GM86809-1 the line circuit breaker. Availability is subject to change without notice. Kohler Co. reserves the right to change the design or specifications without notice and without any obligation or liability whatsoever. Contact your local Kohlerr generator set distributor for availability.