Kohler Decision-Maker 3000 Operation page 17

Industrial generator sets
Hide thumbs Also See for Decision-Maker 3000:
Table of Contents

Advertisement

Digital Inputs Menu
This menu allows the user to review the settings. There
are up to three digital inputs that are programmer
selectable if not reserved by factory options.
There is an optional 2 input/5 output (I/O) module board
available that can provide two additional digital (or
analog) inputs.
The displays for digital inputs appear as shown below
with Values true or false. Items shown in the digital
display as True are active.
D
DIn A1 (digital input A1) standard
D
DIn A2 (digital input A2) standard
D
DIn A3 (digital input A3) standard
D
DIn B1 (digital input B1) with I/O module board
D
DIn B2 (digital input B2) with I/O module board
Changes to the Digital Inputs menu requires the use of
SiteTecht software. The digital input can either open or
close the circuit to activate.
Digital Outputs Menu
This menu allows the user to review the settings. There
is one digital output standard with the controller that is
programmer selectable. The one SPDT switch has
2 amp. contacts at 32 VDC or 0.5 amp. contacts at
120 VAC max.
There is an optional 2 input/5 output (I/O) module board
available that can provide five digital outputs. The
standard digital output on the controller is used to drive
the optional I/O Module board and becomes factory
reserved and no longer available as programmer
selectable.
The displays for digital outputs appear as shown in the
following list with Values as True or False. Items shown
in the digital display as True are active.
D
DOut A1 (digital output A1) standard
D
DOut B1 (digital output B1) with I/O module board
D
DOut B2 (digital output B2) with I/O module board
D
DOut B3 (digital output B3) with I/O module board
D
DOut B4 (digital output B4) with I/O module board
D
DOut B5 (digital output B5) with I/O module board
Changes to the Digital Outputs menu requires the use of
SiteTecht software. The digital output can either open
or close the circuit to activate.
Analog Inputs Menu
This menu allows the user to review the settings. There
is one analog input that is programmer selectable if not
reserved by factory options.
TP-6694 7/11
There is an optional 2 input/5 output (I/O) module board
available that can provide two additional analog (or
digital) inputs.
The displays for analog inputs appear as shown below
with Values of 0--5 volts.
D
AIn A1 (analog input A1) standard
(reserved and not user programmable)
D
AIn A2 (analog input A2) standard
D
AIn B1 (analog input B1) with I/O module board
D
AIn B2 (analog input B2) with I/O module board
Changes to the Analog Inputs menu requires the use of
SiteTecht software.
Event Log Menu
This menu allows the user to review up to 1000 entries of
system events including shutdown faults, warning
faults, and status events. See 1.2.4 Controller Fault
Diagnostics for a list of the items that appear on the
Event Log.
Volt Select Menu
This menu is only available in controller firmware
version 2.8.22 and higher.
Note: The generator set must be stopped before
changing the voltage selection.
This menu allows the user to readily change controller
voltage settings. The volt select feature is typically used
in towable or temporary applications.
Note: The volt select menu requires initial activation by
SiteTecht software.
select True to activate the volt select menu.
Note: The generator set output leads require voltage
reconnection if the generator set does not have a
voltage selector switch installed.
With the generator set stopped, go to the Volt Select
menu.
Then push and hold the pushbutton/rotary
selector dial until the voltage selection starts to flash.
Volt selection is now available. Scroll to the desired
voltage and momentarily press the pushbutton/rotary
selector dial to confirm the voltage selection.
The displays for Volt Select appear as shown in the
following list.
D
120/240 V 1 Ph
D
120/208 V 3 Ph
D
139/240 V 3 Ph
D
277/480 V 3 Ph
D
120/240 V 3 Ph
Section 1 Specifications and Features
In SiteTecht software,
17

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents