Kohler Decision-Maker 3000 Operation page 23

Industrial generator sets
Hide thumbs Also See for Decision-Maker 3000:
Table of Contents

Advertisement

Factory-Defined Settings List
Description
Engine Functions
Critically high fuel level
(diesel-powered models only) *
ECM communications loss
ECM diagnostics (multiple
inputs) [
ECM diagnostics (multiple
inputs) [
ECM faults (address conflict)
ECM faults (model mismatch)
Engine over speed
Engine start aid active
Engine under speed
Fuel tank leak *
Fuel tank leak *
High battery voltage
High coolant temperature
High coolant temperature
High fuel level (diesel-powered
models only) *
Low battery voltage
Low coolant level *
Low coolant temperature
Low cranking voltage
Low engine oil level *
Low engine oil level *
Low fuel level (diesel models) *
Low fuel level (diesel models) *
Low fuel pressure
(gas models) *
Low oil pressure
Low oil pressure
No coolant temperature signal
No oil pressure signal
Overcrank
Speed sensor fault
TP-6694 7/11
Controller Display
Alarm
Message
Horn
Fuel Level Critically
On
High
ECM Comm Err
On
Shutdwn
ECM xxxxxx Warning
On
ECM xxxxxx Shutdwn
On
ECM Addr Err
On
Shutdwn
ECM Mismatch
On
Shutdwn
Eng Speed High
On
Shutdwn
Starting Aid Notice
Eng Speed Low
On
Shutdwn
Fuel Leak Warning
On
Fuel Leak Shutdwn
On
Battery High Warning
On
Coolnt Temp High
On
Warning
Coolnt Temp High
On
Shutdwn
Fuel Level High
On
Warning
Battery Low Warning
On
Coolant Lvl Low
On
Shutdwn
Coolant Temp Low
On
Warning
Lo Crank Vlt Warning
On
Oil Level Low Warning
On
Oil Level Low Shutdwn
On
Fuel Level Low
On
Warning
Fuel Level Low
On
Shutdwn
Fuel Press Low
On
Warning
Oil Press Low Warning
On
Oil Press Low
On
Shutdwn
Temp Sig Loss
On
Shutdwn
Press Sig Loss
On
Shutdwn
Over Crank Shutdwn
On
Spd Sens Flt Warning
On
GenSet
Fault
Write
Mode
Lamp
Access
Always
Warning
Display
Running
Shutdown
SiteTech
Stopped
W
S
W
S
S
S
S
S
A
S
S
A
W
S
W
S
A
W
S
W
W
S
A
S
W
W
W
S
W
S
W
W
S
S
S
S
W
Time
Delay
Range
Default
Range
Setting
Selection
(sec.)
0--100%
95%
0--10
Fixed
0--255
0
105--120%
115%
75--95%
85%
110--135%
125%
Fixed
0--10
(0--30
inhibit)
0--10
(0--30
inhibit)
0--100%
90%
0--10
80--105%
100%
Fixed
Fixed
0--10
16_C
(0--30
Fixed
(60_F)
inhibit)
Fixed
60%
Fixed
0--100%
35%
0--10
0--100%
5%
0--10
Fixed
(Fixed
inhibit)
Fixed
(Fixed
inhibit)
Fixed
Fixed
Section 1 Specifications and Features
Default
Time
Delay
(sec.)
5
10
10
0
(0
inhibit)
0
(0
inhibit)
5
90
5
5
(0
inhibit)
6
10
0
0
(30
inhibit)
5
(30
inhibit)
5
(30
inhibit)
23

Hide quick links:

Advertisement

Table of Contents
loading