Selftest and calibration check

Warning:
Selftest and calibration check can be run in engineering mode only.
This mode is available only when external display, keyboard and mouse are connected
to DATAMAN-848PRO2.
If you feel that your programmer does not react according to your expectations, please
run the programmer (ISP connector's) selftest using the Diagnostic POD (Diagnostic
POD for ISP connectors #2), which is enclosed in the standard delivery package.
Selftest of the programmer
• Insert the 48 pin diagnostic POD - type I into the ZIF socket of the programmer.
Ensure correct orientation of the 48 pin diagnostic POD - type I (see top side of
POD).
• Run the selftest of the programmer in PG4UW menu (Programmer / Selftest plus).
Selftest of the ISP connector
• Insert the Diagnostic POD for ISP connector #2 into the ZIF socket of the
programmer. Ensure correct orientation of the Diagnostic POD for ISP connector
#2.
• Interconnect the 20 pin connector of the Diagnostic POD for ISP connector #2
with the ISP connector of the programmer using the ISP cable included in the
delivery package. Ensure that the pins are interconnected properly (i.e. 1-1, 2-2, ...,
20-20).
• Run the selftest of ISP connector in the PG4UW menu (Programmer / Selftest ISP
connector...).
10