Checking if the sites are ready to be connected
7.
When first starting the Stand-Alone multiprogramming system, or when an error
message "Programmer Sites not found" is displayed, then the programmer
software must be reinitialized by the action "Search for Programmers..."
available in the menu "Programmer / Search for Programmers...".
8.
In the dialog Search for Programmers use the button "Search" to search for
present programmer sites. The result of the search will be displayed in the table
Search results in the Search dialog. When the programmer sites are successfully
found the programmer type and its serial number is shown in the table Search
result. Detected programmers can be accepted by pressing/touching Accept. If
no complete programmer was found, then the "No Programmers found"
message will be displayed in the Search results table and the button Accept will
be disabled.
9.
If the search result is "No Programmers found", please try turning off the Stand-
Alone programmer using menu "File / Shut down computer", turn off the power
button on the back of programmer, wait for 15 seconds or more and start the
programmer again. If the search result is still "No Programmers found", please
refer to the troubleshooting documentation.
Starting programmer sites
10. Each programmer site uses its own hidden control application Pg4uw.
11. To start the hidden applications of the control programmer sites, use menu
"Programmer / Connect Sites".
12. The "Connecting sites" indicator is displayed during connection of the sites.
Additional information about the site connection progress is displayed for each
site in the Status panel on the main screen.
13. Programmer sites are numbered from #1 to #8 in the direction of physical
placement of the programmer sites from left to right.
14. When the connection process of the programmer sites is complete, the indicator
"Connecting Sites" will be hidden. The status panel will contain information
about each site.
Loading project file
15. When the site status after connection is "Ready" or "No project file is loaded"
the user can begin the Load project operation which is accessible from the menu
File / Load project. The project file can be loaded from the default directory
[Projects] or from any other location, for example from a USB FLASH drive. For
more details about the Load project function, refer to the chapter "Menu File" and
Load project. When the Load project operation is successful for all Sites, the
"Ready" status must be displayed in the status panel on the touch screen for all
connected Sites. If there are some Sites with different status use the
troubleshooting documentation to resolve the problem.
Selection of predefined device operation
16. Use the menu "Device / Predefined operation" to select the device Master
operations.
The following Master operations are available:
Blank check
Verify
Program
Erase
For more details about the predefined device operations, see chapter Menu
Device / Predefined operation.
Insertion of devices into the programmers sockets and start of device operations
21