Fault - Angelo Po 1G1CP2G Use And Installation Manual

Pasta cooker
Table of Contents

Advertisement

TROUBLESHOOTING
The appliance has been tested before being put
into service. The information provided below is in-
tended to assist in the identification and correction
of any anomalies and malfunctions which might oc-
cur during use. The user can solve some of these

Fault

Smell of gas.
The pilot light does not ignite.
The pilot light goes out.
The pilot light ignites but the burner
remains off.
The flame is yellow.
Burner control knob is stiff
FAULT
problems himself, but for others specific technical
knowledge or skill is required, and so they must
only be carried out by qualified staff with recognised
experience acquired in the specific sector of opera-
tion.
Causes
Occasional leak because flame has
gone out.
The spark ignition devices are not
working.
Air in pipelines due to long period out of
use.
The thermocouple has not warmed up
enough.
Burner dirty, heat exchange pipes
clogged, condensation drips.
Gas control valve malfunction.
- 9 -
Remedies
Turn off the gas supply tap and
ventilate the room.
Check that the ignition devices are in
good working order. Light by hand
with a naked light.
Important
Contact the after-sales service.
Make more attempts to light the flame.
Make more attempts to light the
flame.
Check the condition of the
thermostat and activate any
ignition enabling device.
Contact the after-sales service.
Contact the after-sales service.
6
IT
AUS
DE
FR
ES

Advertisement

Table of Contents
loading

Table of Contents