  • Page 3: Table Of Contents

    CONTENTS ref. chapters page 0 INFORMATION FOR THE READER ........2 1 GENERAL INFORMATION ..........2 2 TECHNICAL INFORMATION ..........3 PART 3 SAFETY ................5 4 USE AND OPERATION ............5 5 SERVICING ................ 7 6 FAULT ................. 9 7 HANDLING AND INSTALLATION........
  • Page 4: Information For The Reader

    INFORMATION FOR THE READER To find the specific topics of interest to you quickly, re- part: contains all the information necessary fer to the index at the start of the manual. for special categories of reader, i.e. all skilled op- This manual is subdivided into two parts.
  • Page 5: Technical Information

    1) Gas data 5) Serial number 1a) Gas type 6) Test gas indicator frame 1b) Test point pressure 7) Application 1c) Nominal gas consumption 8) Country 2) Model 3) Personalization 4) Manufacture s data PROCEDURE FOR REQUESTING SERVICE Contact one of the authorised service centres for all When requesting service, state the data provide on requirements.
  • Page 6 SAFETY DEVICES Although the appliance is complete with all safety de- vices, during installation and connection additional devices must be added if necessary to comply with the relevant legal requirements. The illustration shows the position of the devices. A)Gas supply tap: for turning the connection to the gas supply line on and off.
  • Page 7: Safety

    SAFETY SAFETY REGULATIONS During design and construction, the constructor has Use the appliance only for the functions intended by the manufacturer. Improper use of the appliance may paid special attention to factors which may cause involve health and safety risks and economic losses. risks to the health and safety of the people interacting with the appliance.
  • Page 8 DESCRIPTION OF CONTROLS The appliance is fitted with the controls for use of its main Off marker Pilot ligh marker functions. A)Burner control knob: for Piezoelectric igni- lighting, turning off and tion marker regulating relative burner and pilot light. B)Piezoelectric ignition knob: for lighting the pilot light.
  • Page 9: Servicing

    LENGTHY APPLIANCE DOWNTIMES If the appliance is to be out of use for a lengthy period, 3 - spread a film of edible oil over the stainless steel proceed as follows: surfaces; 1 - turn off the gas supply tap; 4 - carry out all the servicing procedures;...
  • Page 10 2 - Rinse surfaces with drinking water and dry. Do 4 - Remove food residues immediately before they not use pressurised water jets. set. 3 - Take special care not to damage stainless steel 5 - Remove the limescale deposits which may form on surfaces.
  • Page 11: Fault

    FAULT TROUBLESHOOTING The appliance has been tested before being put into himself, but for others specific technical knowledge or service. The information provided below is intended skill is required, and so they must only be carried out to assist in the identification and correction of any by qualified staff with recognised experience ac- anomalies and malfunctions which might occur dur- quired in the specific sector of operation.
  • Page 12: Handling And Installation

    HANDLING AND INSTALLATION RECOMMENDATIONS FOR HANDLING AND INSTALLATION Important When handling and installing the appliance If necessary, the person authorised to carry comply with the information provided by out these operations must organise a "safe- the constructor directly on the packaging, ty plan"...
  • Page 13 INSTALLATION OF THE APPLIANCE All installation stages must be considered right from IDM-39603302400.tif production of the general layout. Before starting these stages, as well as deciding the place of instal- lation, if necessary, the person authorised to carry out these operations must organise a "safety plan" to protect the people directly involved, and he must also ensure strict compliance with all legal require- ments, especially those relating to mobile work-...
  • Page 14 Always install a quick-closing ON-OFF valve (A) (not supplied).For natural Gas equipment, fit the gas re- gulator (B) supplied with the appliance to gas connec- tion. Caution - warning For natural gas equipment this appliance must be fitted with a Bromic Oara 98 gas re- gulator (AGA Approval N°5862) supplied with the appliance.Do not use any other gas regu- lator.
  • Page 15 Important On completion of the operation, make sure that there are no gas leaks or malfunctions. If converting from Natural gas to Universal LPG make sure the Natural Gas Regulator is removed. TESTING OF THE APPLIANCE 4 - check that the safety thermocouple is working Important correctly;...
  • Page 16 INSTALLATION ON THE FLUE DEFLECTOR 1 - Insert the pivots (1) and (2) both in the holes Fig. A of the deflector (5) and in the upper holes of the flue (8) (see Fig.A). 2 - Fix the pivots (1) and (2) by means of nuts (6) and washer (7).
  • Page 17: Adjustments

    ADJUSTMENTS RECOMMENDATIONS FOR ADJUSTMENTS Important Before making any type of adjustment, acti- In particular, turn off the gas supply tap and vate all the safety devices provided and de- prevent access to all devices which might cide whether staff at work and those in the cause unexpected health and safety haz- vicinity should be informed.
  • Page 18: Replacing Parts

    GREASING THE GAS TAP To carry out this operation, proceed as follows. 1 - Turn off the gas supply tap. 2 - Pull off the knob (A). 3 - Undo the screws (B) and remove the control panel (C). 4 - Undo the screws (D) and extract the cap (E).
  • Page 19 REPLACING THE BURNER AIR BUSHING To carry out this operation, proceed as follows. 1 - Turn off the gas supply tap. 2 - Pull off the knob (A). 3 - Undo the screws (B) and remove the control panel (C). 4 - Slacken the screw (D).
  • Page 20: Annexes

    - ANNEXES - Burner Total Gas consumption Model 40 MJ/h ULPG N. 1 40 MJ/h 40 MJ/h 1G0TP0 - CONNECTION CARD - IDM-39603608400.tif N.G.C. (2) T.G.C. (3) Pilot Flame TPP (1) Supply pressure G.C. Ø (2.1) G.C. Ø (3.1) p (3.2) Ø...