To make the connection, connect the mains line to the
appliance's connection pipe, fitting a shut-off tap (A),
to allow the water supply to be cut off when necessary.
Easily accessible filters must be fitted downstream of
the tap.
To make the connection, connect the mains line to the ap-
pliance's connection pipe, fitting a shut-off tap (A), to al-
low the gas supply to be cut off when necessary.
Important
The tap (A), not supplied with the appliance,
must be installed in an easily accessible posi-
tion and its status (on or off) must be obvious
at a glance.This appliance shall be installed
only by authorised personnel and in ac-
cordance with the manufacturer's instal-
lation
instructions,
regulations, municipal building codes,
water supply regulations, electrical wir-
ing regulations, AS 5601/AG 601 - Gas Installa-
tions and any other statutory regulations.
Always install a quick-closing ON/OFF valve (A) (not
supplied).For Natural Gas equipment,fit the gas regula-
IT
tor(B) supplied with the appliance to gas connection.
AUS
Caution - warning
For natural gas equipment this appliance must be fitted with a Bromic Oara 98 gas regulator (AGA
DE
Approval No.5862) supplied with the appliance. Do not use any other gas regulator.Ensure re-
gulator is fitted with respect to the gas flow marked on the housing of the regulator.