Restoring Upx-2 Default Settings - Crestron UPX-2 Operation Manual

Crestron upx-2 universal presentation processor: operations guide
Hide thumbs Also See for UPX-2:
Table of Contents

Advertisement

Universal Presentation Processor
Operations Guide – DOC. 6276B
UPX-2 Troubleshooting (Continued)
TROUBLE
"Communication Error
UPX-2 is unable to
with Control System" is
communicate with
displayed when demo
control system.
project loaded.
"Invalid Path" displayed
Path not specified or
in MediaMarker Session
no Flash memory
Information window.
installed.
A "Restrictions" message
Enable Pop-ups not
appears.
checked.

Restoring UPX-2 Default Settings

To restore the default settings of the UPX-2:
1. Connect to the UPX-2 as described in "Establishing Communications
Between the PC and the UPX-2" on page 59.
2. Open a console window in Crestron Toolbox and type the command
RESTORE. This command will affect the following parameters:
IP Table: All IP table entries are deleted.
Video/RGB settings: Settings are reset to "0".
Net ID: Reset Net ID to 03.
Display Output will be set to 1024 x 768.
Project Working Path: The Project Working Path will be set to
user\display.
Internet Security settings: High for Internet sites, Medium for
Intranet, Low for Trusted sites. Trusted sites list is restored to
crestron.com and 192.168.*.*.
Standby Timeout: Standby Timeout will be reset to 10 minutes.
Console settings: Restored to factory defaults (115200 Baud, no
parity, 8 data bits, 1 stop bit).
Mouse cursor show/hide status: Restored to factory default setting:
"Hidden".
Ethernet Settings: TCP/IP properties will change to DHCP.
Mapped Drives: All mapped drives will be cleared.
Admin Username and Password: Admin Username and Password
will be set to upxadmin.
Hostname and Workgroup name: The hostname and workgroup
name of the touchpanel will reset to their factory defaults.
CAUTION: Do not turn off power to the UPX-2 while it is restoring the
default settings. Damage may occur.
POSSIBLE
CORRECTIVE ACTION
CAUSE(S)
Check CUZ file version.
Check UPX-2 Cresnet ID.
Check for or load demo program in
control system.
Specify network path or install Flash
memory in PC Card slot A or B.
Open SETUP MENU | Embedded Apps
and click checkbox.
Universal Presentation Processor: UPX-2 ¥ 75
Crestron UPX-2