Setup

Operations Guide – DOC. 6276B

Rack Mounting

WARNING: To prevent bodily injury when mounting or servicing this unit in a
rack, take special precautions to ensure that the system remains stable. The
following guidelines are provided to ensure your safety:
The unit should be mounted at the bottom of the rack if it is the only unit in
the rack.
When mounting this unit in a partially filled rack, load the rack from the
bottom to the top with the heaviest component at the bottom of the rack.
Mounting of the equipment in the rack should be such that a hazardous
condition is not achieved due to uneven mechanical loading.
If the rack is provided with stabilizing devices, install the stabilizers before
mounting or servicing the unit in the rack.
NOTE: To prevent overheating, do not operate this product in an area that exceeds
the environmental temperature range listed in the table of specifications.
Consideration must be given if installed in a closed or multi-unit rack assembly since
the operating ambient temperature of the rack environment may be greater than the
room ambient. Contact with thermal insulating materials should be avoided on all
sides of the unit.
NOTE: Installation of the equipment in a rack should be such that the amount of air
flow required for safe operation of the equipment is not compromised.
NOTE: Consideration should be given to the connection of the equipment to the
supply circuit and the effect that overloading of circuits might have on overcurrent
protection and supply wiring. Appropriate consideration of equipment nameplate
ratings should be used when addressing this concern.
NOTE: Reliable earthing (grounding) of rack-mounted equipment should be
maintained. Particular attention should be given to supply connections other than
direct connections to the branch circuit. (e.g., use of power strips).
NOTE: If rack mounting is not required, rubber feet are provided for tabletop
mounting or stacking. Apply the feet near the corner edges on the underside of the
unit.
Two rack "ears" are provided with the UPX-2 so that the unit can be rack mounted.
These ears must be installed prior to mounting. Complete the following procedure to
attach ears to the unit. A #2 Phillips screwdriver is required.
1. Using a #2 Phillips screwdriver, remove the three screws closest to the front
panel from one side of the unit.
2. Position a rack ear so that its mounting holes align with the holes vacated
by the screws in step 1.