Calibrate The Touchpanel - Crestron UPX-2 Operation Manual

Crestron upx-2 universal presentation processor: operations guide
Hide thumbs Also See for UPX-2:
Table of Contents

Advertisement

Universal Presentation Processor
Operations Guide – DOC. 6276B
"Display Output" Window

Calibrate the Touchpanel

If the DTT-15V2 or DTT-17 requires calibration, access the UPX-2 SETUP MENU
described in "Accessing the SETUP MENU" on page vi.
Refer to "Touch Screen" on page 30 for additional calibration information.
1. Click Touch Screen | Crestron DualTouch and Cybertouch or Wacom
USB | Calibrate and follow the directions for touch and pen calibration.
2. Click Save and Reboot to save your changes.
CAUTION: At power up or reboot, the touchpanel will cycle through
colors and the Crestron logo screen for approximately 2.5 minutes prior to
displaying the progress bar. This is a normal part of the boot up process. Do
not turn off power to the UPX-2 while it is rebooting. Damage may occur.
NOTE: Touchpanel calibration is required after a firmware upgrade.
NOTE: If a touchpanel is disconnected and reconnected to a different port,
or reconnected with a hub connecting to the UPX-2, the touchpanel must be
recalibrated.
If necessary, you can also access the internal setup screen for the touchpanel. Refer
to "Display Settings" in the appropriate guide: DTT-15V2 Operations Guide (Doc.
6342), or DTT-17 Operations Guide (Doc. 6343), available from the Crestron
website.
Crestron UPX-2
Universal Presentation Processor: UPX-2 ¥ xiii

Advertisement

Table of Contents
loading

Table of Contents