useful for holding results at runtime (such as storing intermediate computational
results for use later on in the program), but their results do not persist between
powerdowns.
The symbols that cause this warning are: (The speedkey name follows in
parenthesis)
Analog RAM (RAM)
Digital RAM(DRAM)
Analog Non-Volatile Ramp (RAMPNV)
Serial RAM (SMEM, SRAM)
Serial RAM from database (SMEM2, SRAMDB)
Serial Memory Search (ISMEM, SMSEARCH)
Analog RAM from database (RAM2, RAMDB)

WARNING (CMCVT158)

CN-TVAV has simulated clock – time must be manually reset at system startup.
Some control systems do not have a hardware clock, such as the CEN-TVAV and the
CN-TVAV. The clock must be reset at system startup.
The symbols that cause this warning are: (The speedkey name follows in
parenthesis)
Serialize Date (DATE$)
Clock Driver (DEVICE SYSTEM,CLOCK)

WARNING (CMCVT159)

Symbol S-1 in macro S-5 (Macro file c:|\crestron\usrmacro\mymacro\umc) is
incomplete.
The specified symbol in the specified macro file has been flagged as incomplete
(marked with *!*). This should be fixed before continuing. An incomplete symbol is
one that is missing inputs, outputs, or parameters.

WARNING (CMCVT160)

Symbol S-5 is incomplete.
The specified symbol has been flagged as incomplete (marked with *!*). This should
be fixed before continuing. An incomplete symbol is one that is missing inputs,
outputs, or parameters.