Crestron/User Database Dialog Error; User Interface Dialog Error; Connection Sheet Dialog Error; Communication Dialog Error - Crestron SW-SIMPL Installation & Operating Manual

Crestron sw-simpl software: install guide
Table of Contents

Advertisement

Software
184 • Crestron SIMPL Windows
Similarly, the device library and symbol library also are updated, and SIMPL
Windows files must be opened by the same or later versions, or risk containing
undefined devices or symbols.
Similarly, the Crestron macro collection and user macro collection should contain all
of the macros that are used in the SIMPL Windows program. If not, a placeholder
macro is used, and the connections are preserved, but the program cannot be
successfully compiled. Get the missing macro and place it in the user macro
directory. Exit SIMPL Windows and restart, or go to Edit | Preferences and hit OK
to reload the libraries.
Each SIMPL Windows program must contain a control system before it can be
compiled and loaded. Macros are not standalone programs and cannot have control
systems.

Crestron/User Database Dialog Error

Some information is missing from the "Device Info" tab of the device, possibly due
to a Crestron database or user database error, or to program integrity problems.
Try re-installing the Crestron database, or rebuilding the user database.

User Interface Dialog Error

Some information is missing from the "UI" tab of the device, or the specified
VisionTools project cannot be found or is the wrong format.

Connection Sheet Dialog Error

Some information is missing from the "Connection Sheet" tab of the device, possibly
due to program integrity problems.

Communication Dialog Error

Some information is missing from the "Serial Settings" tab of the device, possibly
due to program integrity problems.

DSG Not Found Error

You have attempted to access the Crestron Design & Specification Guide (DSG);
and this error message appeared. The DSG is accessed directly by SIMPL Windows
Help menu or by selecting a Device in the Device Library and pressing F1 for
product information.
Make sure the DSG is installed on the PC's hard drive and/or re-install the DSG
from the ControlCD.
If You Do Not Have the Crestron ControlCD:
Please call Crestron at 1.888.CRESTRON [1.888.273.7876] to obtain your free copy.
Alternatively, you may visit the Crestron web site: www.crestron.com.
Crestron SIMPL™ Windows
Installation & Operations Guide – DOC. 5728C