ERROR (CMCVT131)

Number of Analog Signals exceeds system capacity
A given Cresnet system has certain limitations. If the compiler detects that one of
these limitations has been exceeded, one or more of these messages may be issued.
The status that comes up at the end of the compile will have the particular limitation
flagged with a "*" in front of the message.

ERROR (CMCVT132)

Required NVRAM exceeds system capacity.
A given Cresnet system has certain limitations. If the compiler detects that one of
these limitations has been exceeded, one or more of these messages may be issued.
The status that comes up at the end of the compile will have the particular limitation
flagged with a "*" in front of the message.

ERROR (CMCVT133)

Program size exceeds system capacity.
A given Cresnet system has certain limitations. If the compiler detects that one of
these limitations has been exceeded, one or more of these messages may be issued.
The status that comes up at the end of the compile will have the particular limitation
flagged with a "*" in front of the message.

NOTICE (CMCVT134)

Cannot find parameter #VAL1 for substitution in S-5 (prompt string) in Macro
S-1 (Macro File C:\cresvss\usrmacro\replacements.umc), assuming 0 (Use
quotes if this is a literal parameter).
If a parameter replacement is given but is not valid, this error occurs. For example, if
on a DELAY symbol the time is given as #VAL1 but VAL1 does not exist anywhere
on the Define Arguments symbol, this error is given when the program is compiled.
The argument to the symbol is then set to 0.

FAILURE (CMCVT135)

Could not process C:\cresvss\usrmacro\replacements.umc, macro resync
required.
If a macro was used in a program and then modified such that it's number of inputs
or outputs have changed, the compiler will see this discrepancy when it tries to load
the macro when generating the output binary file.
In order to fix this, the Re-Synch Macros in Program option must be selected from
SIMPL Windows. It is possible that more inputs or outputs will be added to the
symbol, in which case the macro will now be incomplete. It is also possible that
inputs or outputs will be deleted from the symbol.
Note that ANY time macros are changed, the program using them should be
resynched. If signal types are changed on a macro, the compiler will not catch this.