Program Load/Save Error; Swapping Devices Error; Error In Moving A Device; Autofill Error - Crestron SW-SIMPL Installation & Operating Manual

Crestron sw-simpl software: install guide
Table of Contents

Advertisement

Software
182 • Crestron SIMPL Windows
report them to Crestron along with a description of what you were doing when they
occurred, and a saved version of your program both before and after the problem
occurred.
Errors of this kind should be quite rare, and most DO NOT affect the ability to use
your program, but simply reflect errors in disposing of older information that is no
longer needed. They are an attempt to detect any problem, no matter how small,
when it occurs, before it can propagate and become a bigger problem.
We recommend saving your program on a regular basis, perhaps with the
AUTOSAVE feature, in order to invoke the consistency checking.

Program Load/Save Error

These errors occur when a program is loaded or saved, and have the usual causes for
failing to find or open a file. Check that:
1. The file exists, the name is spelled correctly, you have read/write/delete privileges
for the file, and if saving, that the file is writable. (In Windows Explorer, see the file,
right click and choose Properties and see if the file is read-only.)
2. If the file is on a network, make sure that the network accepts long file names if
the file's name is not DOS compatible (8.3 format).
3. If saving, that the disk has enough room to save the file.
4. If the file is on a network, make sure that no one else is simultaneously using the
file.

Swapping Devices Error

There is an error in attempting to interchange the addresses of two devices.
Check that:
1. One or both devices could be built-in, and therefore its address cannot be changed.
2. The devices may be of two different address types, perhaps one is a card and the
other is a network device, and they cannot be interchanged.

Error in Moving a Device

There is an error in attempting to interchange the addresses of two devices.
Check that:
1. The device could be built-in, and therefore its address cannot be changed.
2. You may be trying to move the device to a different address type.
Perhaps it is a card and is moving to a network address, and that cannot be allowed.
3. There may be a limitation on the address range of the device. For example, the
CNIORACK has only one settable hexadecimal digit for an address, and must reside
in network address range 03-0F.

AutoFill Error

Make sure that your control system is connected via its "computer port" to your PC's
serial port. Drag and drop a control system of the appropriate type to the
Configuration Manager, then select Autofill.
Crestron SIMPL™ Windows
Installation & Operations Guide – DOC. 5728C