Setting Backup Software
3) Execute the sg.build command to add the target settings to the
4) Execute the sg.install command to install the sg driver on the server.
5.1.3
Setting a robot type and drive type
1) Open the Media and Device Management window from the NetBackup
2) Set the robot type and drive type as follows:
5-2
cd /usr/openv/volmgr/bin/driver
/usr/openv/volmgr/bin/sg.build sg.conf -mt N -sc ./sg.conf
/usr/openv/volmgr/bin/driver/sg.conf file. Use the -mt option to specify the
maximum values for the target IDs of the LT160 controller and drive.
/usr/sbin/rem_drv sg
rm -f /kernel/drv/sg.conf
/opt/openv/volmgr/bin/driver/sg.install
*1 The sg driver is installed automatically when NetBackup is installed. When
editing the configuration definition file of the sg driver, use the rem_drv
command to delete the driver, then reinstall the driver.
Administration window, and add a robot and a drive from the Action menu on the
menu bar.
•
Robot type: TLD
•
Drive type: hcart
C144-E073-01EN