6.
Hardware Configurations
Drive Enclosure
I/O Modules
The I/O module is a component that controls how the controller and the drives interact.
The I/O module is connected to the controller or an I/O module on another drive enclosure.
A drive enclosure has two I/O modules, which makes it possible for a failed I/O module to be replaced while the
system is running.
■
Drive Interface Ports
This port is for connecting controller enclosures or drive enclosures.
The drive interface port has an IN port and an OUT port.
This section provides the specifications for drive interface ports when 2.5" type drive enclosures and 3.5" type
drive enclosures are used.
Table 14 Drive Interface Port Specification (I/O Module, 2.5" Type DE/3.5" Type DE)
Interface
SAS
The high-density drive enclosure specifications are shown below.
Table 15 Drive Interface Port Specification (I/O Module, High-Density DE)
Interface
SAS
Fan Expander Module (FEM)
An FEM is a cooling fan module. Two FEMs are installed in a high-density drive enclosure.
If one of the FEMs fails, the failed FEM can be replaced while the system is running.
Power Supply Units
The power supply unit transforms input AC power from a power socket to DC power and supplies power to each
component. Each power supply unit contains fans.
A 2.5" type drive enclosure and a 3.5" type drive enclosure have two power supply units, which makes it possible
for a failed unit to be replaced while the system is running.
A high-density drive enclosure has four power supply units and up to two failed units can be replaced while the
system is running.
Transfer rate (max.)
12Gbit/s
Transfer rate (max.)
12Gbit/s
6Gbit/s
80
FUJITSU Storage ETERNUS DX500 S3/DX600 S3 Hybrid Storage Systems Overview
Copyright 2019 FUJITSU LIMITED
Connector type
miniSAS HD (SFF-8644)
Connector type
miniSAS HD (SFF-8644)
Number of ports for each I/O
module
1 (IN)
1 (OUT)
Number of ports for each I/O
module
1 (IN)
1 (OUT)
P3AM-7702-29ENZ0