Nortel Meridian 1 Administration And Maintenance page 400

Table of Contents

Advertisement

Page 386 of 492
553-3011-311
Standard 7.0
Chapter 8 — Service changes and maintenance
8H
DSL 0 transceiver failure
9H
DSL 1 transceiver failure
AH
DSL 2 transceiver failure
BH
DSL 3 transceiver failure
CH
DSL 4 transceiver failure
DH
DSL 5 transceiver failure
EH
DSL 6 transceiver failure
FH
DSL 7 transceiver failure
BRI201
DSL reports layer 1 status. For SILCs in network terminator (NT) mode, the
possible status conditions can be:
0H
S/T transceiver failure
1H
Physical (layer 1) is activated successfully
2H
Physical (layer 1) is de-activated successfully
3H
Physical (layer 1) is losing synchronization
4H
Physical (layer 1) is in the process of being established
5H
Physical (layer 1) failed to get established
For SILCs in terminal equipment (TE) mode, the possible status conditions
can be:
0H
S/T interface transceiver failure
1H
Physical (layer 1) is activated successfully
2H
Deactivation was requested from far end
3H
Physical (layer 1) is losing synchronization
4H
Physical (layer 1) is in the process of being activated
5H
Physical (layer 1) failed to get established