Nortel Meridian 1 Administration And Maintenance page 177

Table of Contents

Advertisement

Chapter 5 — ISDN BRI line and packet data implementation
Table 7
Cable types and short passive SILC DSL lengths
Cable type
Outside PIC
Outside PIC
Outside PIC
Outside PULP
Outside PULP
Outside PULP
Inside riser
Inside riser
Inside riser
Inside Z station (FT1)
Inside Z station (FT4)
Inside type D (3 and 4 pair)
Inside type D (25 pair)
Gauge
AWG
22
24
26
22
24
26
22
24
26
22
22
24
24
Option 11C
ISDN BRI Administration and Maintenance
Page 163 of 492
Maximum DSL
length
ft (m)
560 (170)
540 (165)
510 (155)
560 (170)
560 (170)
520 (160)
590 (180)
540 (165)
490 (150)
490 (150)
460 (140)
490 (150)
480 (145)

Advertisement