Nortel Meridian 1 Administration And Maintenance page 283

Table of Contents

Advertisement

Chapter 6 — ISDN BRI trunk implementation
Note: Observe the LED on the faceplate of the MISP while performing
the next step.
3
Insert the MISP into the selected card slot and lock it in place.
The LED should light, flash three times then remain lit to indicate
that the MISP is operating correctly but is not configured and
enabled.
—or—
The LED should light, flash three times then extinguish to indicate that
the MISP is operating correctly and is configured and enabled.
Any other LED indication suggests a defective MISP circuit card.
Note: The Flash ROM can become corrupted if loss of power occurs
during programming of the Flash ROM. If this occurs, the Flash ROM
will automatically be re-initialized when the MISP is installed (powered
up). This operation will delay the completion of the self-test, and it will
take five minutes for the LED to flash three times.
4
Repeat the steps of this procedure for each MISP being installed.
Option 11C
ISDN BRI Administration and Maintenance
Page 269 of 492

Advertisement