Nortel Meridian 1 Administration And Maintenance page 333

Table of Contents

Advertisement

To perform a B-channel packet data transmission test:
1
From a ISDN BRI B-channel packet data terminal, dial another
local or a remote ISDN BRI packet data terminal and establish an
active call connection.
2
After the call originating ISDN BRI terminal receives an
acknowledgment message that the receiving ISDN BRI terminal is
ready, the call originating ISDN BRI terminal can start transmitting
packet data.
3
Verify that the transmitted data has been received successfully by
checking transmitted information for accuracy.
You can read the information on the screen or print it on the local printer.
4
Perform this test between two ISDN BRI terminals on the Option 11
for local transmission and between an Option 11 ISDN BRI terminal
and a remote ISDN BRI terminal over the network.
5
Release the connection.
You may wish to repeat the above test on several ISDN BRI packet data
terminals.
To perform a D-channel packet data transmission test:
1
From an ISDN BRI D-channel packet data terminal, dial another
ISDN BRI packet data terminal and establish an active call
connection.
2
After the call originating ISDN BRI terminal receives an
acknowledgment that the receiving ISDN BRI terminal is ready, the
call originating ISDN BRI terminal can start transmitting packet
data.
3
Verify that the transmitted data has been received successfully by
checking transmitted information for accuracy.
You can read the information on the screen or print it on the local printer.
4
Perform this test between two ISDN BRI terminals on Option 11 for
local transmission and between an Option 11 ISDN BRI terminal
and a remote ISDN BRI terminal over the network.
5
Release the connection.
Option 11C
Chapter 7 — Acceptance testing
ISDN BRI Administration and Maintenance
Page 319 of 492