FCC Conformity

US Installations only: Federal Communications Commission (FCC) rules
WARNING: Changes or modifications not expressly approved by
Siemens could void the user's authority to operate the equipment.
Notes:
• This equipment has been tested and found to comply with the limits for a Class A
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference when the equipment is
operated in a commercial environment.
• This equipment generates, uses, and can radiate radio frequency energy and, if not
installed and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a residential
area is likely to cause harmful interference to radio communications, in which case
the user will be required to correct the interference at his own expense.

CE Electromagnetic Compatibility (EMC) Conformity

This equipment has been tested and found to comply with the following EMC Standards:
EMC Standard
CISPR 11:2004/EN 55011: 2009, CLASS A
EN 61326-1: 2006
IEC 61326-1: 2005
EN61000-3-2: 2006
EN61000-3-3: 2008
A1: 2001 + A2: 2005
EN61000-4-2:2009
EN61000-4-3:2006
EN61000-4-4:2004
EN61000-4-5:2006
Page 4
SITRANS LUT400 (HART) – OPERATING INSTRUCTIONS
Title
Limits and methods of measurements of radio
disturbance characteristics of industrial, scientific,
and medical (ISM) radio-frequency equipment.
Electrical Equipment for Measurement, Control and
Laboratory Use – Electromagnetic Compatibility.
Electromagnetic Compatibility (EMC) Part 3-2: Limits
for harmonic current emissions (equipment input
current
16A per phase).
Electromagnetic Compatibility (EMC) Part 3-3:
Limitation of voltage changes, voltage fluctuations,
and flicker in public low voltage supply systems, for
equipment with rated current
not subject to conditional connection.
Electromagnetic Compatibility (EMC) Part 4-2:Testing
and measurement techniques – Electrostatic
discharge immunity test.
Electromagnetic Compatibility (EMC) Part 4-3:
Testing and measurement techniques – Radiated,
radio-frequency, electromagnetic field immunity test.
Electromagnetic Compatibility (EMC) Part 4-4:
Testing and measurement techniques – Electrical
fast transient/burst immunity test.
Electromagnetic Compatibility (EMC) Part 4-5:
Testing and measurement techniques – Surge
immunity test.
16A per phase and
A5E33329501