Parshall Flume

Note: C = Converging Dimension.
Front View
* The transducer must be above the maximum head by at least the blanking value (see
Range
).
Application information
Sized by throat width
Set on solid foundation
For rated flows under free flow conditions, the head is measured at
the converging section from the beginning of the throat section
Parameter
2.15. 1 . Primary Measuring Device (PMD)
2.15.3.2. Flow Exponent
2.15.3.3. Maximum Head
2.15.3.4. Maximum Flow at 20 mA
b
2.15.4.1. K Factor
a.
Typical Flow Exponent range for Parshall Flume; consult your flume documen-
tation.
b.
Required for exponential device absolute calculation only.
A5E33329501
Plan View
Side View
Zero
Head
SITRANS LUT400 (HART) – OPERATING INSTRUCTIONS
C
2
/
C
3
transducer*
Value
Exponential Devices
a
1.522–1.607
flow
Q
2.2.4. Near
2
/
the length of
3
Page 101