CLMD16 Configuration Guide___________________________________
Note:
Because of the use of a "Counter Element" the same Windshield Wiper Control behavior will
not be able to be replicated inside the internal logic of any equipment having direct control
accessibility to the ECBs including N2KView® or any third party MFD using 1275000 Load
Controller PGN. If this logical circuit needs to be accessed by third party MFD, a single
combinatory "Logic Element" can be inserted into the circuit allowing "Network Input" control of
this circuit as long as the signal is a momentary type of Input Signal. The mapping for this
exact circuit would look as shown below:
52
CLMD16 Configuration Guide Rev.1.1