Toggle a Load On / Off from Multiple Momentary Input Sources Plus a
"Toggle Network Input"
Similar to toggling a load On / Off from multiple momentary input sources, this circuit type adds
a "Toggling Network Input" signal into the circuit. When a CLMD16 ECB is in "Toggle Mode"
the ECB will toggle the state from its current state of "On" or "Off" to the opposite state when
the following occurs: The Rising Edge or "On" detection of an ECB "Toggle Network Input" or
the Rising Edge or "On" detection of a direct ECB "Input Signal". This operational mode will
allow for a "Toggle Network Input" which could come from a third party MFD using 127500
Load Controller PGN or any equipment running Maretron's N2KView® software plus any
applied direct ECB "Input Signal" to toggle the ECB in harmony with each other. Tip: When an
ECB is in "Toggle Mode" a "Momentary Network Input" signal becomes unaffected by the
"Toggle Mode".
In the following example, there will be two momentary input sources and one "Toggle Network
Input" signal used to switch a single CLMD16 load in a Toggle fashion. One input is from a
hardwired switch that has a momentary DC (-) signal called "Binary Event Low" and one input
is a momentary Discrete I/O input called "Discrete I/O 1". There is the additional influence on
the ECB of one externally set (Direct access through 127500 PGN) "Toggle Network Input"
signal. Take note that no different action is required to setup this circuit type than the
"Toggle a
Load On / Off from Multiple Momentary Input
Sources" circuit above. The only difference is the
"Toggle Network Input" (shown in red) has access to the ECB setup by the message's
origination equipment, may it be a third party MFD using 127500 Load Controller PGN or any
equipment running Maretron's N2KView® software. Because the ECB is in "Toggle Mode" the
ECB's "Input Signal" and "Toggle Network Input" will work in harmony with each other toggling
the ECB On / Off.