CLMD16 Configuration Guide___________________________________
In the following circuit configuration example, there will be two momentary input sources used
to switch a single CLMD16 load in a toggle fashion. One input is from a hardwired switch that
has a momentary DC (-) signal called "Binary Event Low" and one input is a momentary
Discrete I/O input called "Discrete I/O 1", both will be used to toggle the single CLMD16 load.
The following steps shows how to accurately configure this circuit type.
Step 1:
Assign inputs to a "Logic Element". Where "0" is Off and "1" is On, configure the "Logic Output"
in a manner to where if any input source is On, the "Logic Element's Output" becomes active.
Step 2:
Place "Logic Output" signal into desired ECB control "Input Signal" and turn on "Toggle Mode".
18