Toggle A Load On / Off From Multiple Momentary Input Sources - Maretron M-Power CLMD16 Configuration Manual

16 channel dc load controller module
Hide thumbs Also See for M-Power CLMD16:
Table of Contents

Advertisement

____________________________________________________________
Step 2:
Place "Logic Output" signal into desired ECB control "Input Signal".

Toggle a Load On / Off from Multiple Momentary Input Sources

When toggling a circuit On / Off, not all input sources are treated equally. For example, a
"Discrete I/O" input could be a momentary input requiring a "Toggle Element" added to it. A
"Binary Event" (Item hardwired to an Input to the CLMD16) is subject to be whichever physical
switch style the installer chooses; therefore, the input could be a sustained contact and no
"Toggle Element" will be needed. Multi-Function Displays (MFDs) using 127500 Load
Controller PGN or any equipment running Maretron's N2KView® software could have direct
access to the CLMD16's ECB channels and the CLMD16 configuration will not be able to
change the Digital Switching origination command for this type of equipment. Most MFDs
Digital Switching commands are "Toggle style Network Input" by default. For these reasons, it
is vitally important that the configurator understands the characteristics of each input type used
for CLMD16 load switching for proper configuration.
CLMD16 Configuration Guide Rev.1.1