Because a third party MFD using 127500 Load Controller PGN or any equipment running
Maretron's N2KView® software, by default, will have direct access to control ECB #s 1 & 2
Separately (Breakers #1 & 2), the "Toggle Sequence" shown here will only operate via
"Discrete I/O 1". The same "Toggle Sequence" behavior may be able to be replicated inside
the internal logic of the equipment having direct control accessibility (N2KView®) or if this logic
needs to be accessed by third party MFD, "Manual Mode" can be enabled to both ECBs
severing this direct control access. A combinatory "Logic Element" can be inserted before
"Toggle Element 1" and "Latch Element 1" to enable the same "Toggle Sequence" behavior via
"Network Input 1" as long as the signal is a momentary type of Input Signal. The mapping for
this exact circuit would look as shown below: