____________________________________________________________
Step 3:
Setup ECB parameters. Ensure "Toggle Mode" is On. Place the "Logic Output" into the "Input
Signal" and be sure to select "PWM" as the ECB "Type" this will allow for the entry of the
"Counter".
Note:
If this circuit does not operate, please ensure parameter settings defining "Binary Event Low"
and "Binary Event High" are set in accordance with the defining voltages that the CLMD16 will
be receiving from your input source.
Single Input Load Control Sequence
(CLMD16 Does Something Different each Time the Same Button is Pressed)
In the following example there is a circuit that has two loads, one load is called "Fwd. Deck
Lights" and one load is called "Aft Deck Lights". It is the desire for this circuit to operate from a
single input (Discrete I/O 1) where "Press 1" turns On "Fwd Deck Lights", "Press 2" turns On
"Aft Deck Lights", "Press 3" turns On both, "Press 4" turns both Off. See the following example
steps to setup a circuit of this type.