CLMD16 Configuration Guide___________________________________
To:
Step 4:
Now, Using the newly created "Binary Event High" signal, add this signal to the interjected
"Logic Element" and place the original freshwater control "Input Signal" that was "Network
Input 4" into the "Logic Element" as well. Select the logic element's output parameters such
that when the "Binary Event High" signal is met the "Logic Output" turns off consequently
turning off the freshwater pump.

Timed Delay Circuit Upon Input Detection

This Circuit uses a "Timer Element". In this example there will be a "Delay Off" signal used to
"Time" a load named "Generator Preheat" that needs to be triggered by "Discrete I/O 4"
(Momentary Input). The generator requires a 10s timed signal to preheat the generator. See
following steps to setup a circuit of this type.
34