Polarity Reversing (H-Bridge) Or Motor Direction Control Circuit - Maretron M-Power CLMD16 Configuration Manual

16 channel dc load controller module
Hide thumbs Also See for M-Power CLMD16:
Table of Contents

Advertisement

____________________________________________________________
Note:
Because a third party MFD using 127500 Load Controller PGN or any equipment running
Maretron's N2KView® software, by default, will have direct access to control the above-
mentioned ECBs (#1-3) the "Navigation Lights Logic" circuit shown here will only operate via
"Discrete I/O 1 & 2". The same "Navigation Lights Logic" behavior may be able to be replicated
inside the internal logic of the equipment having direct control accessibility (N2KView®) or if
this logic needs to be accessed by third party MFD, "Manual Mode" can be enabled severing
this direct control access. Two combinatory "Logic Elements" can be inserted before the "Logic
Elements 1 & 3" to enable the same "Navigation Lights Logic" behavior via "Network Inputs 1 &
2" as long as the signal is a momentary type of Input Signal. The mapping for this exact circuit
would look as shown below:

Polarity Reversing (H-Bridge) or Motor Direction Control Circuit

Use this circuit type to control any load requiring reversing polarity up to 12A. Apply this circuit
to a motor or some electric actuators to reverse directionality. Setting up this circuit type
requires a one step process unless adding multiple control points. To add control points, apply
the control points to a "Logic Element" then plug the "Logic Output" into the ECBs "Input
Signal". Breakers 1,2 and 11,12 are capable of reverse polarity drive. The step required to
setup this circuit type is to change EBC "Type" to "Full-Bridge" or "Soft Start Full-Bridge" See
following Dialog to see configuration example.
CLMD16 Configuration Guide Rev.1.1
27