CLMD16 Configuration Guide___________________________________
Step 3:
Apply "Flash Output" to Mast Strobe ECB. Ensure Toggle Mode is Off.
Note:
Because a third party MFD using 127500 Load Controller PGN or any equipment running
Maretron's N2KView® software, by default, will have direct access to control ECB #8 (Breaker
#8), the "Flash Element" shown here will only operate via "Discrete I/O 8". The same "Flash"
behavior may be able to be replicated inside the internal logic of the equipment having direct
control accessibility (N2KView®) or if this logic needs to be accessed by third party MFD,
"Manual Mode" can be enabled severing this direct control access. A combinatory "Logic
Element" can be inserted before the "Toggle Element" to enable the same "Flash" behavior via
"Network Input 8" as long as the signal is a momentary type of Input Signal. The mapping for
this exact circuit would look as shown below:
30
CLMD16 Configuration Guide Rev.1.1