Configurating Output Channels
Where the CLMD16's ECB profiles are configured, the "General Tab" should be the second if
not first configuration point when configuring CLMD16 then visited again as the last stop to
finalize the configuration. This method is recommended because the "General Tab" is where
the ECB circuit names, and ECB "Type" is configured. By configuring the CLMD16's ECB or
Output Channels into the configuration first you then know where the final destination of the
Inputs or abovementioned "Switching Elements" will go as Input Signals to the ECB channel.
There are 5 ECB "Types" to choose from:
1) DC
(Standard On / Off Channel)
2) PWM / PWM W/Counter
(Pulse-Width Modulation Enabled)
3) Soft Start DC
(Standard On / Off Channel with Soft Start Enabled)
4) Full-Bridge
(Reversing Polarity / H-Bridge Enabled)
5) Soft Start Full-Bridge
(Reversing Polarity / H-Bridge with Soft Start Enabled)
See following dialog to acquaint yourself with ECB configuration.
CLMD16 Configuration Guide Rev.1.1