6.6.6 OTU Advanced Config Screen

The settings on this screen should not normally need to be changed.
Simple UTC Output Priority
Priority of the Simple UTC force bits, relative to other force bits such as those
from MOVA. Range 0 to 50, with 50 being the highest priority. The default is 21.
UTC Type 2 Output Priority
Priority of the UTC Type 2 force bits, relative to other force bits such as those
from MOVA. Range 0 to 50, default 20.
UTC Type 2 instation is NTP server
When this item is Enabled, the instation IP address is used to set the NTP server
address. When Disabled, the NTP server address is defined on the
"StatusConfig - Advanced Config - Network - NTP" screen. Default Enabled.
UTC Type 2 Past Command window (seconds)
This is the earliest time difference from now for which SNMP SET requests will
be accepted. Commands received with timestamp of more than this number of
seconds before the current time will be ignored and an out-of-time-range error
will be placed in the system log. Range 1 to 300 seconds. Default 10 seconds.
UTC Type 2 Future Command window (seconds)
This is the latest time difference from now for which SNMP SET requests will be
accepted. Commands received with timestamp of more than this number of