Re-Initialising Mova - Siemens UTMC OTU Handbook

Table of Contents

Advertisement

7.2.1 Re-initialising MOVA

If it is required to clear the MOVA data sets and working data, then the
command can be used:
movaini1
movaini2
movaini3
movaini4
If the command is not recognised, the MOVA application for that stream must be started
running (to view running applications, use the web interface and display the "System"
web screen).
When the command is executed, the MOVA data sets, MOVA working data, MOVA
error logs, flow logs and assessment logs for that MOVA stream are restored to the first
time start-up state. Other MOVA streams will be unaffected.
In the case of MOVA 7 the OTU should then be rebooted to ensure clean erasure of
TMA log data from the file system and working memory.
667/HB/31601/000
Siemens MOVA Commissioning Complete
- this will initialise MOVA stream 1
-
"
"
-
"
"
-
"
"
"
stream 2
"
stream 3
"
stream 4
Page 79
UTMC OTU/MOVA Handbook