2.3.2.2.2 5CAMPC.0020-11
2.3.2.2.2.1 General information
A straight-through
control
The pinout of the
Ethernet
If the first
Ethernet interface
make sure that crossover (MDIX) is not enabled.
Stop / Emergency stop (6 wires)
2 wires not used
Enable switch (6 wires)
2 wires not used
RS232 (3 wires)
Not used
CAN + shield (5 wires)
Not used
Information:
A
control
cabinet cable is used for the Mobile Panel 7100, Mobile Panel 40/50 and Mobile Panel 100/200
product series. Not all wires are used when wiring Mobile Panel 7100 and Mobile Panel 40/50 devices,
which limits their functionality compared to Mobile Panel 100/200 devices.
The surface is protected against water, oil (lubricating and hydraulic oils per
lubricant.
The
control
cabinet cable is fastened to the
- Drilling template" on page
connector. The remaining lines have an open end with wire end sleeves to make it easier to wire to
and other interfaces.
2.3.2.2.2.2 Order data
Model number
Short description
Control
5CAMPC.0020-11
Mobile Panel
-
Optional accessories
Accessories
4MPCBX.0000-00
Mobile Panel connection box - For cables with push-pull circular
connectors
4MPCBX.0000-C01
SIT MP connection box PP
4MPCBX.0001-00
Mobile Panel small connection box - For cables with push-pull
circular connectors
2.3.2.2.2.3 Technical data
Information:
The following specified characteristic data, features and limit values are only valid for these individual
components and may differ from those of the complete system. The data specified for the complete
system applies to the complete system in which this individual component is used, for example.
Model number
General information
Certifications
CE
GOST-R
Cable construction
Type
Mobile Panel 40/50 User's manual V1.80
cabinet cable is required for the wiring inside the
connector (1:1) makes it possible to connect directly to a standard
on B&R
Ethernet hub
Power supply
+ grounding
(3 wires)
Ethernet RJ45 +
Shield (4 wires)
Figure 39: 5CAMPC.0020-11 - Mobile Panel
control
65). The other end of the
cabinet cables
control
cabinet cable - Push-Pull circular connector
Ethernet
straight-through - 2 m
Table 27: 5CAMPC.0020-11 - Order data
Table 28: 5CAMPC.0020-11 - Technical data
AC808 (model number 0AC808.9) is used, it is important to
control
cabinet door via the connection housing
control
cabinet cable has a pre-assembled RJ45
5CAMPC.0020-11
Straight-through
control
cabinet.
Ethernet
Receptacle
for push-pull locking mechanism
cabinet cable
EN
60811 Part 2-1) and cooling
(see Fig. 41 "Receptacle
safety
Figure
Yes
Yes
Technical data
hub.
Ethernet
equipment
63