6.5 Box cable

6.5.1 5CAMPB.0100-10

6.5.1.1 General information

A box cable establishes the electrical connection between the
4MPCBX.0000-00. It includes lines for the network
vices or stop / emergency stop and key switches or pushbuttons, enable switches, serial transfer and CAN.
The connection side has a pre-assembled RJ45
wire end sleeves to make it easier to wire to
the connection box on the other side (connection box side).
Enable switch
(6 wires)
RS232
(3 wires)
CAN 1 & CAN 2
+ shield
(5 wires)
Power supply
+ grounding
(3 wires)
The pinout of the
Ethernet
or to the 1st
Ethernet
connection (MDIX) on B&R
If a different
Ethernet hub
The surface is protected against water, oil (lubricating and hydraulic oils per
lubricant.

6.5.1.2 Order data

Model number
Short description
Accessories
5CAMPB.0100-10
Mobile Panel box cable - With wire end sleeves - With connector
contacts

6.5.1.3 Technical data

Information:
The following specified characteristic data, features and limit values are only valid for these individual
components and may differ from those of the complete system. The data specified for the complete
system applies to the complete system in which this individual component is used, for example.
Model number
General information
Certifications
CE
GOST-R
Cable construction
Type
Properties
Supply lines
Material
Permissible operating voltage
EN
60950 requirements must be observed; see section "+24 VDC power supply" of the user's manual.
3)
118
Ethernet
safety
Connection side for
Control cabinet
Control devices
(6 wires)
Ethernet RJ45 +
Shield (4 wires)
Figure 81: 5CAMPB.0xxx-10 - Connections
RJ45 connector (crossover) makes it possible to connect it directly to a B&R
Ethernet hub
is used, it must support crossed over RX and TX lines.
Table 68: 5CAMPB.0100-10 - Order data
Table 69: 5CAMPB.0100-10 - Technical data
control
(Ethernet
10/100 Mbit/s), 24 VDC power supply
connector. The remaining lines have an open end and
equipment and other interfaces. The box cable is installed in
Key switch or
Pushbutton (ST6)
(2 wires)
Cable gland
CAN 1 & CAN 2
+ shield
(ST3) (5 wires)
AC808 (model number 0AC808.9).
5CAMPB.0100-10
Yes
Yes
Hybrid cable, 25 wires
Halogen- and silicone-free
Tinned copper stranded wire
30 VDC
cabinet and connection box
3)
Connection box side
Stop / Emergency stop (ST5)
(4 wires)
Enable switch (ST7)
(6 wires)
RS232 (ST4)
(3 wires)
Power supply
+ grounding (ST1)
(3 wires)
M3 cable lug
Female Ethernet RJ45 connector + shield
(ST2) (4 wires)